Siemens 5SY4105-5 — 1-Pole MCB (DIN Rail)

Siemens 5SY4105-5 SENTRON MCB, 1P, Characteristic A, 10kA/35

MPN5SY4105-5
Active

Siemens SENTRON 5SY4105-5 miniature circuit breaker, 1-pole, Characteristic A, 10 kA per EN 60898-1 / 35 kA per IEC 60947-2, 400 V AC, 18 mm wide.

$68.15Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4105-5 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4105-5 — Electrical & Protection
ParameterValue
Tripping characteristic classA
Overvoltage categoryIII
5SY4105-5 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4105-5 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

That's the key fit condition: this breaker goes in a DC-bus or solid-state load circuit, not a general-purpose motor branch (where you'd use C or D curve). Breaking capacity is dual-rated: 10 kA per EN 60898-1 and 35 kA per IEC 60947-2. For a 400 V AC industrial panel with a transformer upstream, the 35 kA rating is what you size against. The IP20 rating applies with conductors connected — standard for inside a closed panel, no washdown exposure.

Approvals include IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 / CSA C22.2 No. 235 — meaning it passes acceptance for European distribution boards and North American industrial panels. The UL 1077 rating is 5 kA (supplementary protector), so for UL-listed panels the fault-current capability is lower than the IEC figure.

Integration notes

Mounting position any — no derating for horizontal or inverted orientation. Combined terminal at both top and bottom — accepts cable or busbar connection without swapping parts.

Frequently asked questions

What is the closest functional second-source for 5SY4105-5?

Within the SENTRON family, the 5SY4140-7 is a higher-current variant (40 A vs. 5 A) with the same 1-pole form factor and Characteristic A curve. For a direct drop-in replacement at the same rating, stick with the 5SY4105-5; the 5SY4140-7 will not fit without rewiring if the load current differs.

What compliance documentation does Siemens provide for 5SY4105-5?

The breaker carries IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 / CSA C22.2 No. 235 approvals. It is halogen-free and silicon-free; RoHS/REACH declarations are standard with the SENTRON series.

Where can I buy 5SY4105-5?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.