Skip to main content
Siemens 5SY4105-8CC11 — 1-Pole MCB (DIN Rail)

Siemens 5SY4105-8CC11 SENTRON MCB, 1P D 0.5A 10kA

MPN5SY4105-8CC11

Siemens SENTRON 5SY4105-8CC11, 1-pole miniature circuit breaker, D tripping characteristic, 0.5 A rated current, 10 kA breaking capacity per EN 60898, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4105-8CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4105-8CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4105-8CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4105-8CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The 18 mm width occupies a single modular unit on a DIN rail, which is the standard spacing for 1-pole MCBs in a distribution board. Depth is 76 mm (70 mm installation depth), so it fits flush in most enclosures without protruding past the gland plate. Mounting position is any orientation — no derating required for horizontal or inverted installation. The quick-assembly fastening system snaps onto the rail without tools. Combined terminals at both top and bottom accept supply from either end, which simplifies busbar wiring in a multi-pole assembly. The neutral conductor is not switched — this is a single-pole device switching only the phase.

Temperature derating

The 0.5 A rating is at 35 °C ambient. At elevated temperatures the continuous current must be derated: 0.46 A at 40 °C, 0.44 A at 45 °C, 0.41 A at 50 °C, 0.39 A at 55 °C, and 0.36 A at 60 °C. The operating range spans -40 °C to 75 °C, with humidity limits of 95% up to 55 °C, 55% up to 70 °C, and 35% at 75 °C.

Frequently asked questions

Where can I buy 5SY4105-8CC11 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the D-curve and why does this MCB have it?

The D tripping characteristic means the magnetic trip fires at 10 to 20 times the rated current (5 to 10 A for this 0.5 A unit), which is designed for loads with high inrush — small transformers, solenoid valves, or DC power supplies — where a B or C curve would nuisance-trip on startup.

What compliance documentation does this brand provide for 5SY4105-8CC11?

The MCB is designed to EN 60898 for breaking capacity (10 kA) and carries pollution degree 3 and overvoltage category III ratings per IEC 60947-2. The housing is halogen-free and silicon-free. Specific RoHS, REACH, and UL documentation should be confirmed at quote time from the supplier.

Will 5SY4105-8CC11 drop into a panel specified around a different 5SY MCB?

Yes — all 5SY series MCBs share the same 18 mm modular width, 70 mm installation depth, DIN-rail mounting, and combined terminal layout. A panel wired for a 5SY4101-7CV or 5SY4116-7CV will accept this unit without rewiring, provided the D-curve and 0.5 A rating match the circuit requirements.

MPN
5SY4105-8CC11