Siemens SENTRON 5SY4106-6-ZW07 miniature circuit breaker, 1-pole, B characteristic, 10 kA (IEC 60898-1), 35 kA (IEC 60947-2), 18 mm width, 76 mm depth, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4106-6-ZW07 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4106-6-ZW07 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY4106-6-ZW07 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4106-6-ZW07 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

It occupies one modular width unit (18 mm) on a DIN rail, with a 76 mm depth and 90 mm height — fits standard 1-module cutouts in SENTRON distribution boards or any 35 mm DIN-rail enclosure.

The 10 kA rating under IEC 60898-1 is the standard for domestic and light commercial distribution; the 35 kA under IEC 60947-2 is the industrial rating that tells a panel builder this MCB can clear higher prospective fault currents in an industrial supply. Operating temperature range of -40 °C to 75 °C covers most outdoor and unheated plant environments, though the derating curve above 40 °C (max 95% RH at 55 °C, dropping to 35% at 75 °C) means the breaker's thermal trip may shift — factor that into the load calculation if the panel sits near a furnace or in direct sunlight.

Installation depth is 70 mm (the body is 76 mm deep, but the 70 mm figure accounts for the rail and wiring space).

Certified to IEC / EN 60898-1 (the general MCB standard for household and similar installations) and IEC / EN 60947-2 (the industrial circuit-breaker standard for higher fault levels). Also carries UL 1077 and CSA C22.2 No. 235 recognition — the 5 kA rating under UL 1077 is the North American supplementary-protector rating, which means it's accepted as a branch-circuit protective device in UL 508A industrial control panels when used within its marked interrupting rating.

Frequently asked questions

Where can I buy 5SY4106-6-ZW07 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

Will 5SY4106-6-ZW07 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 1-pole SENTRON MCBs with the same 18 mm width and DIN-rail mounting, so the physical fit is identical. The difference is the tripping characteristic: 5SY4106-6-ZW07 is B-curve (3-5x In), while 5SY4140-7 is a different curve — check the existing panel's load type before swapping, as a B-curve may nuisance-trip on inductive loads that a C-curve would handle.

What compliance documentation does Siemens provide for 5SY4106-6-ZW07?

The MCB carries IEC/EN 60898-1, IEC/EN 60947-2, UL 1077, and CSA C22.2 No. 235 certifications. It is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations. Standard documentation includes the declaration of conformity and the datasheet with detailed ratings.