Skip to main content
Siemens 5SY4106-8CC11 — 1-Pole MCB (DIN Rail)

Siemens 5SY4106-8CC11 SENTRON MCB, 1P, D-curve, 10 kA

MPN5SY4106-8CC11

Siemens SENTRON 5SY4106-8CC11, miniature circuit breaker, 1-pole, D tripping characteristic, 10 kA per EN 60898, 400 V AC, 72 V DC, 1 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4106-8CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4106-8CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4106-8CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4106-8CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY4106-8CC11 is a 1-pole miniature circuit breaker with a D tripping characteristic, rated 10 kA breaking capacity per EN 60898 at 400 V AC and 72 V DC maximum. Designed for railway applications, it mounts on a DIN rail (1 modular width unit, 18 mm wide) and accepts any mounting position. The D-curve means it tolerates high inrush currents — typical for motor or transformer loads — without nuisance tripping, while still clearing a short-circuit fault up to 10 kA.

Integration & Mounting

Snap-on DIN rail mount, 1 MW (18 mm wide). Installation depth 70 mm; overall depth 76 mm. Combined terminals top and bottom accept busbar or wire. Sealable — allows tamper-proofing in metering or safety circuits. Halogen-free and silicon-free construction matters for clean-room or semiconductor fab environments where outgassing contaminates processes.

Frequently asked questions

Where can I buy 5SY4106-8CC11?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the closest functional second-source to 5SY4106-8CC11?

The 5SY4101-7CV is a peer in the same SENTRON family but with a C-curve (lower inrush tolerance). If your application needs the D-curve for motor or transformer loads, the 5SY4106-8CC11 is the correct choice — the C-curve sibling may nuisance-trip on high inrush.

Will 5SY4106-8CC11 drop into a panel specified around 5SY4101-7CV without rewiring?

Yes — same 1 MW footprint, same DIN-rail mount, same terminal layout. The only difference is the tripping characteristic (D vs C). No rewiring needed.

What compliance documentation does Siemens provide for 5SY4106-8CC11?

The part carries a railway-application design and is rated per EN 60898. Halogen-free and silicon-free construction supports clean-room and semiconductor fab compliance. Full RoHS/REACH/UL/IEC documentation is available from Siemens on request.

MPN