Siemens 5SY4108-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY4108-6 SENTRON MCB, B-Curve, 1-Pole, 10/20 kA

MPN5SY4108-6
Active

Siemens SENTRON 5SY4108-6, miniature circuit breaker, 1-pole, B-curve, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 18 mm width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4108-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4108-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY4108-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4108-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

SENTRON 5SY4108-6 — 1-pole B-curve MCB for panel and load-center protection

The Siemens SENTRON 5SY4108-6 is a 1-pole miniature circuit breaker with B-curve tripping characteristic, rated 10 kA breaking capacity per IEC/EN 60898-1 and 20 kA per IEC/EN 60947-2 / UL1077. That dual standard means it covers both residential / light commercial (EN 60898) and industrial panel (IEC 60947-2) applications — the higher 20 kA figure matters when the fault current at the panel bus is above 10 kA. It occupies one modular width (18 mm) on a DIN rail, depth 76 mm, IP20 with conductors connected.

The 10 kA (EN 60898) figure is the default for most building distribution boards; the 20 kA (IEC 60947-2) rating applies when the breaker is installed in an industrial panel with higher prospective fault current.

Panel integration — DIN rail, 1 MW, any mounting position

Fastening method is quick-assembly system — snaps on and off without tools. Any mounting position allowed. Depth behind panel is 70 mm (installation depth), overall depth 76 mm. Sealable for tamper-proof applications.

Frequently asked questions

What is the breaking capacity of 5SY4108-6?

10 kA per IEC/EN 60898-1 and 20 kA per IEC/EN 60947-2 / UL1077 — the higher figure applies in industrial panel applications.

Where can I buy 5SY4108-6?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What compliance standards does 5SY4108-6 meet?

It complies with IEC/EN 60898-1, IEC/EN 60947-2, and UL1077. Halogen-free and silicon-free design. Pollution degree 3, overvoltage category III.