Siemens 5SY4113-7CV MCB 1P C 13A 15kA IEC 60947-2

MPN5SY4113-7CV

Siemens 5SY4113-7CV, 1-pole miniature circuit breaker, C-curve, 13 A rated, 15 kA breaking capacity per IEC 60947-2, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4113-7CV — Identification
ParameterValue
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4113-7CV — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY4113-7CV — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4113-7CV — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

MCB for panel protection — 13 A C-curve, 15 kA

The Siemens 5SY4113-7CV is a 1-pole miniature circuit breaker with C-curve trip characteristic, rated 13 A at 35 °C and 250 V AC single-phase.

Thermal derating and ambient constraints

The 13 A rating holds at 35 °C; at 40 °C it derates to 11.56 A, and at 50 °C to 9.9 A. The operating range spans -40 °C to 75 °C, with humidity limits of 95% RH up to 55 °C, tapering to 35% RH at 75 °C.

Mounting position is unrestricted — vertical, horizontal, or inverted — which simplifies layout in crowded sub-distribution boards. IP20 with conductors connected, so it's intended for enclosed panel use, not washdown areas.

Frequently asked questions

What is the breaking capacity of 5SY4113-7CV?

15 kA per IEC 60947-2, which covers most commercial and light industrial sub-distribution applications.

Where can I buy 5SY4113-7CV?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a binding offer.

Does 5SY4113-7CV drop into a panel specified for 5SY4116-7CV?

Yes — both are 1-pole C-curve MCBs in the same 18 mm modular width with identical mounting and terminal layout. The difference is the current rating: 5SY4113-7CV is 13 A, 5SY4116-7CV is 16 A. No rewiring needed if the load is within 13 A.

What compliance documentation does 5SY4113-7CV carry?

It is certified to IEC / EN 60947-2, halogen-free and silicon-free. The standard covers the breaking capacity and safety requirements for industrial and commercial installations.

MPN
5SY4113-7CV