Skip to main content
Siemens 5SY4115-7CV — 1-Pole MCB (DIN Rail)

Siemens 5SY4115-7CV MCB, 1P C-Curve 1.6A, 15kA IEC 60947-2

MPN5SY4115-7CV

Siemens 5SY4 series MCB, 1-pole C-curve 1.6 A, 15 kA breaking capacity per IEC/EN 60947-2, 18 mm width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4115-7CV — Identification
ParameterValue
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4115-7CV — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY4115-7CV — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4115-7CV — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY4115-7CV is a 1-pole miniature circuit breaker with C-curve tripping characteristic, rated 1.6 A at 230/400 V AC and carrying a 15 kA breaking capacity per IEC/EN 60947-2.

The 1.6 A rating holds at 35 °C ambient. At 40 °C it derates to 1.48 A; at 50 °C to 1.4 A; at 55 °C to 1.29 A. The maximum operating temperature is 75 °C, with humidity limits of 95 % up to 55 °C, tapering to 35 % at 75 °C. The storage range goes down to -40 °C, so it handles cold warehouses before installation.

Panel fit and compliance

Sealable (can be locked in OFF position with a padlock hasp). Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — fine for machine-mounted sub-panels but not for direct engine mounting.

Frequently asked questions

Where can I buy 5SY4115-7CV and what is the lead time?

We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send the quantity you need and we'll get you a firm number.

Will 5SY4115-7CV drop into a panel specified around 5SY4104-7CV without rewiring?

Yes — both are 1-pole C-curve MCBs in the same 18 mm wide, 76 mm deep 5SY4 family. The 5SY4104-7CV is a 0.4 A variant; this 5SY4115-7CV is 1.6 A. Same footprint, same DIN-rail clip, same terminal layout. If the panel was wired for a 1-pole 5SY4, this swaps in directly — just verify the higher current rating matches your load.

What compliance documentation does Siemens provide for 5SY4115-7CV?

The breaker is designed and tested to IEC/EN 60947-2, which is the standard for industrial MCBs. It carries the CE mark for the European market. Halogen-free and silicon-free construction is declared. For RoHS, REACH, or specific UL documentation, check the Siemens Industry Online Support portal — the datasheet and declarations are published there under the 5SY4 family.

MPN
5SY4115-7CV