5SY4116-7CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SY4116-7CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)10 kA
Overvoltage categoryIII
5SY4116-7CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4116-7CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY4116-7CC11 is a 1-pole miniature circuit breaker rated 16 A with a C tripping characteristic and a 10 kA breaking capacity at 400 V AC per EN 60898.

Sizing and fit in the panel

The 70 mm installation depth plus the quick-assembly mounting means it fits into compact enclosures without needing extra clearance behind the rail. Mount it in any position — vertical, horizontal, upside down — and it still trips at the same calibrated curve. Both top and bottom terminals accept combined screw/clamp connections, so you can land a ring tongue or a bare wire without swapping parts. Touch protection is built in — no accidental finger contact on the energized bus bar after installation.

Where it belongs on the line

This breaker is designed for mechanical engineering and industrial environments, not residential lighting panels. The 400 V AC rated voltage covers three-phase line-to-line circuits common in control cabinets; the 440 V single-phase and multi-phase rating gives you margin on a 480 V system. It also carries a DC rating up to 72 V — handy for control-power circuits in the same enclosure. The IP20 protection class (with conductors connected) is typical for a DIN-rail MCB inside a closed panel — no washdown rating here, so keep it behind a gland plate or enclosure door.

For a panel originally built with the 5SY4116-7CV peer, the 5SY4116-7CC11 shares the same 18 mm width, 1-pole footprint, C16 rating, and 10 kA breaking capacity — it drops into the same DIN slot without rewiring. The difference is in the terminal design or accessory compatibility; verify the terminal type if your panel uses a specific busbar or shunt.

Frequently asked questions

What is the breaking capacity of 5SY4116-7CC11?

10 kA at 400 V AC per EN 60898, which covers most panelboard fault-current scenarios in commercial and light industrial installations.

Will 5SY4116-7CC11 replace 5SY4116-7CV without panel changes?

Yes — same 18 mm width, same 1-pole C16 rating, same 10 kA breaking capacity. The physical footprint and DIN-rail mounting are identical; verify the terminal style if your busbar is specific to the -7CV variant.

Where can I buy 5SY4116-7CC11?