Siemens 5SY4116-8CC11 — 1-Pole MCB (DIN Rail)

Siemens 5SY4116-8CC11 SENTRON MCB, 1P D 16 A, 10 kA

MPN5SY4116-8CC11

Siemens SENTRON 5SY4116-8CC11 miniature circuit breaker, 1-pole D-curve 16 A, 10 kA breaking capacity, 18 mm width, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY4116-8CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry

Electrical & Protection

5SY4116-8CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Overvoltage categoryIII

Mounting & Connection

5SY4116-8CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes

Environmental

5SY4116-8CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY4116-8CC11 is a SENTRON miniature circuit breaker rated 16 A at 400 V AC with a D tripping characteristic and a 10 kA breaking capacity per EN 60898. The D curve means it tolerates high inrush currents — typically specified for motor circuits, transformers, or welding equipment where the startup surge would nuisance-trip a B or C curve. Breaking capacity at 10 kA is the standard domestic and light commercial fault level; if your prospective short-circuit current exceeds that, you need an upstream current-limiting device or a higher-rated breaker.

Panel fit and environment

At 18 mm wide (1 MW), this single-pole breaker snaps onto a DIN rail via the quick-assembly system. The 76 mm depth and 70 mm installation depth leave room for wiring in a standard 100 mm deep enclosure. Terminals accept 0.75 to 35 mm² solid or stranded — that's a wide range, covering both control-circuit wiring and larger feeder conductors. Screw terminals torque to 2.5 to 3.5 N·m. IP20 with connected conductors means the busbar area is finger-safe once wired, but the breaker itself is not sealed against moisture; keep it inside a panel rated for the environment.

Frequently asked questions

What is the breaking capacity of 5SY4116-8CC11?

10 kA per EN 60898 at 400 V AC. That is the standard domestic and light commercial fault level.

Where can I buy 5SY4116-8CC11?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SY4116-8CC11 drop into a panel specified for 5SY3132-6?

The 5SY4116-8CC11 is a 1-pole D-curve 16 A breaker; the 5SY3132-6 is a different pole count and characteristic. They share the same 18 mm width and DIN-rail mounting, but the tripping curve and current rating differ — verify the circuit requirements before substituting.

What compliance documentation does this brand provide?

The SENTRON series carries EN 60898 certification for breaking capacity. The part is halogen-free and silicon-free, which supports RoHS and REACH compliance. Specific declarations are available from the manufacturer upon request.

MPN
5SY4116-8CC11