Skip to main content
Siemens 5SY4132-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY4132-7CC SENTRON MCB, C-Curve, 1P, 10 kA

MPN5SY4132-7CC

Siemens SENTRON 5SY4132-7CC, 1-pole miniature circuit breaker, C-curve, 10 kA breaking capacity per EN 60898, 400 V AC, 1 MW unit width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4132-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4132-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY4132-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4132-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY4132-7CC — SENTRON 1-pole MCB, C-curve, 10 kA

The 10 kA rated value per EN 60898 is the short-circuit capacity at 230/400 V; under UL 1077 and CSA C22.2 No. 235, the same breaker is rated 5 kA, which governs its use in North American supplementary-protection applications. Single-pole design means it switches only the phase — neutral is not switched, so it pairs with a separate neutral bar or a 2-pole breaker when full isolation is required.

Mounting position is any, which simplifies layout in crowded enclosures.

Rated for ambient temperatures from -40 °C to +75 °C, with humidity derating per: max 95% RH up to 55 °C, tapering to 35% at 75 °C. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

Frequently asked questions

Can I install auxiliary contacts or shunt trips on this breaker?

Yes, the 5SY4132-7CC accepts supplementary devices (auxiliary contacts, shunt trips, alarm switches) via the product extension feature.

Will the 5SY4132-7CC fit in a panel designed for a 5SY4116-7CV?

Yes — both are 1-pole, 1-MW-unit SENTRON MCBs with identical 18 mm width, 76 mm depth, and DIN-rail mounting. The 5SY4132-7CC drops into the same panel footprint without rewiring, provided the C-curve and higher current rating match the circuit requirements.

MPN
5SY4132-7CC