Siemens 5SY4140-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY4140-6 SENTRON MCB, 1P B-Curve 40A 10kA IEC

MPN5SY4140-6
Active

Siemens SENTRON 5SY4140-6, 1-pole miniature circuit breaker, B-curve, 40 A rated, 10 kA (IEC 60898-1) / 15 kA (IEC 60947-2), 18 mm wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4140-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4140-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY4140-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4140-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY4140-6 — B-curve 40 A MCB, dual-standard breaking capacity

It carries a 10 kA breaking capacity per IEC/EN 60898-1 and a 15 kA rating per IEC 60947-2 / UL1077, so it covers both residential-distribution board specs and industrial panel SCCR requirements under a single order code. At 40 A it is a common feeder or submain breaker in a 1-MW (18 mm) footprint.

Temperature derating — what the 40 A rating actually delivers

The 40 A rating holds at 35 °C ambient. Above that it derates linearly: 37.56 A at 40 °C, 36.28 A at 45 °C, 34.96 A at 50 °C, 33.6 A at 55 °C, and 32.16 A at 60 °C. If the panel ambient runs at 50 °C, plan for a 35 A continuous load, not 40 A.

Dual-standard breaking capacity — panel vs. distribution board

Rated 10 kA under IEC/EN 60898-1 (the standard for household and similar installations) and 15 kA under IEC 60947-2 / UL1077 (industrial control-panel standard).

Panel fit — 1 MW wide, 76 mm deep, any mounting position

The quick-assembly fastening system snaps onto the rail without tools. Mounting position is unrestricted — vertical, horizontal, or flat — which simplifies layout in crowded enclosures.

Certified to IEC/EN 60898-1 and IEC 60947-2 / UL1077. Halogen-free and silicon-free construction. Energy limitation class 3. Sealable terminals (top and bottom combined terminals) allow tamper-proofing in metered or safety-critical circuits. The surrounding temperature influence spec (max 95% RH to 55 °C, derating above) is standard for this class.

Frequently asked questions

What is the breaking capacity of 5SY4140-6?

10 kA per IEC/EN 60898-1 and 15 kA per IEC 60947-2 / UL1077. The 15 kA rating is the one to use for industrial panel SCCR calculations.

What is the difference between 5SY4140-6 and 5SY4140-7?

Both are 1-pole 40 A SENTRON MCBs. The 5SY4140-6 has a B-curve (3–5× In); the 5SY4140-7 has a C-curve (5–10× In). The -6 is for resistive and general loads; the -7 is for moderate inrush loads like small motors or banks of LED drivers. They share the same footprint, breaking capacity, and terminal layout — no rewiring needed to swap one for the other, but the trip curve must match the load type.

Where can I buy 5SY4140-6?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Siemens provide for 5SY4140-6?

The MCB carries certifications to IEC/EN 60898-1 and IEC 60947-2 / UL1077. It is halogen-free and silicon-free. Standard Siemens documentation includes the declaration of conformity and the datasheet with the full derating curves.