Siemens 5SY4140-6KK11 — 1-Pole MCB (DIN Rail)

Siemens 5SY4140-6KK11 SENTRON MCB, 1P 40A B-Curve, 10kA

MPN5SY4140-6KK11

Siemens SENTRON miniature circuit breaker, 5SY4140-6KK11, 1-pole, 40 A rated current, B tripping characteristic, 10 kA breaking capacity per EN 60898, 15 kA per IEC 60947-2, 18 mm width, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4140-6KK11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SY4140-6KK11 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)10 kA
Energy limitation class3
Overvoltage categoryIII
5SY4140-6KK11 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4140-6KK11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

1-pole 40 A B-curve MCB for panel and railway duty

It occupies a single 18 mm modular width on the DIN rail and is rated for a breaking capacity of 10 kA per EN 60898 and 15 kA per IEC 60947-2, giving it headroom for high-fault utility connections or industrial sub-distribution. The part is designated for railway applications, with halogen-free and silicon-free construction, and carries IP20 protection with connected conductors.

The 40 A rating at 35 °C is the nominal; derate to 37.56 A at 40 °C, 36.28 A at 45 °C, 34.96 A at 50 °C, 33.6 A at 55 °C, and 32.16 A at 60 °C. In a warm panel — say 50 °C ambient — expect the breaker to carry 34.96 A continuously without tripping. The 10 kA (EN 60898) and 15 kA (IEC 60947-2) ratings mean it can safely interrupt faults at those levels; the IEC 60947-2 figure is the one to use for industrial panel SCCR calculations.

Frequently asked questions

What is the breaking capacity of 5SY4140-6KK11?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The IEC figure governs industrial panel SCCR.

Will 5SY4140-6KK11 drop into a panel specified around 5SY4116-6CC?

Yes — both are 1-pole SENTRON MCBs in the same 18 mm width, same DIN-rail footprint, same terminal layout. The 5SY4140-6KK11 is rated 40 A versus the 16 A of the 5SY4116-6CC, so wiring and upstream protection must be sized for the higher current, but the mechanical fit is identical.

Where can I buy 5SY4140-6KK11?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY4140-6KK11