Siemens 5SY4203-8CC11 — 2-Pole MCB (DIN Rail)

Siemens 5SY4203-8CC11 SENTRON MCB, 2-Pole D 3 A, 10 kA

MPN5SY4203-8CC11

Siemens SENTRON 5SY4203-8CC11 miniature circuit breaker, 2-pole, D tripping characteristic, 3 A rated current, 10 kA breaking capacity at 400 V AC, 72 V DC max, 2 width units (36 mm).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4203-8CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4203-8CC11 — Electrical
ParameterValue
Number of poles2
5SY4203-8CC11 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4203-8CC11 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

The D tripping characteristic is the main selection differentiator. D-curve breakers have a magnetic trip threshold of 10 to 20 times the rated current (In). For this 3 A unit, that means the magnetic trip activates between 30 A and 60 A. That's deliberately high — it avoids tripping on the inrush of small motors, solenoid valves, or transformers where the initial surge can be 8-12x the running current. D is specifically for inductive loads with high starting peaks. In a panel with a transformer rating that limits prospective short-circuit current to under 10 kA, this breaker coordinates cleanly. For higher fault levels (e.g., close to a large transformer), you'd need a higher interrupting rating or a current-limiting upstream device. The DC rating of 72 V max means it's suitable for 48 V or 60 V DC control circuits, but not for 110 V DC battery banks.

Frequently asked questions

How do I get current pricing and availability for 5SY4203-8CC11?

Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the distributor channel for a current quote.

What is the difference between 5SY4203-8CC11 and 5SY3132-6?

The 5SY3132-6 is a different rating and curve within the same SENTRON 5SY family. The 5SY4203-8CC11 is a 2-pole D-curve 3 A breaker; the 5SY3132-6 is a different order code with its own rating. They share the same form factor and mounting, but the tripping characteristic and current rating differ — verify your load requirements before substituting.

What is 5SY4203-8CC11's listed depth?

The depth is 76 mm, with an installation depth of 70 mm. Width is 36 mm (2 width units), height is 90 mm.

What conductor sizes does 5SY4203-8CC11 accept?

It accepts solid conductors from 0.75 to 35 mm² and stranded conductors from 0.75 to 35 mm². The screw terminals require a tightening torque of 2.5 to 3.5 N·m.

Will 5SY4203-8CC11 drop into a panel specified for 5SY3132-6 without rewiring?

Both are 2-pole SENTRON breakers on the same 36 mm footprint, so the mechanical fit and busbar connection are identical. However, the electrical ratings (current and tripping curve) differ — confirm the load's inrush and continuous current match the 5SY4203-8CC11's D-curve and 3 A rating before swapping.