Skip to main content
Siemens 5SY4204-7CC11 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SY4204-7CC11 MCB, 2P C-Curve 4A 10kA

MPN5SY4204-7CC11

Siemens SENTRON 5SY4204-7CC11 miniature circuit breaker, 2-pole, C-curve, 4 A rated, 10 kA breaking capacity per EN 60898, 50/60 Hz, IP20, for railway applications.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4204-7CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4204-7CC11 — Electrical
ParameterValue
Number of poles2
5SY4204-7CC11 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY4204-7CC11 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4204-7CC11 — Environmental
ParameterValue
Pollution degree3
5SY4204-7CC11 — Specifications
ParameterValue
Energy Limitation Class3

Product details

Siemens SENTRON 5SY4204-7CC11 — 2-pole C-curve MCB, 4 A, 10 kA

The Siemens SENTRON 5SY4204-7CC11 is a 2-pole miniature circuit breaker rated 4 A with a C-curve tripping characteristic and a 10 kA breaking capacity per EN 60898. It's designed for 50/60 Hz AC systems and carries a pollution degree 3 rating, overvoltage category III — typical for industrial panel distribution in mechanical engineering and industry environments.

At 4 A rated, it's sized for a branch circuit feeding a small motor or control transformer, not a main feeder. The 2-pole configuration switches both line and neutral on a single-phase or split-phase circuit.

Temperature derating — the real-world current

Above that, derate linearly: 3.76 A at 40 °C, 3.64 A at 45 °C, 3.5 A at 50 °C, 3.37 A at 55 °C, 3.23 A at 60 °C (–). If your panel ambient runs 50 °C, plan for 3.5 A continuous load max — not the 4 A label. The operating range spans -40 °C to 75 °C (–), with humidity limits up to 95% at 55 °C, tapering to 35% at 75 °C.

Width is 36 mm (2 modular units), depth 76 mm, height 90 mm, installation depth 70 mm.

Frequently asked questions

Will 5SY4204-7CC11 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 2-pole SENTRON MCBs with the same 36 mm width, DIN-rail mount, and combined terminals. The 5SY4204-7CC11 is a 4 A C-curve unit; the 5SY4140-7 is a 40 A unit. If the panel was wired for a 40 A circuit, dropping in a 4 A breaker would trip immediately on load — the physical fit is fine, but the ampacity mismatch means you'd need to re-evaluate the branch circuit load.

What compliance documentation does this brand provide for 5SY4204-7CC11?

The product is designed per EN 60898, carries pollution degree 3 and overvoltage category III, and is halogen-free and silicon-free. It's classified per IEC 81346-2 and DIN EN 61346-2 as function code F. Standard Siemens documentation includes RoHS and REACH declarations available on request.

How do I get current pricing and availability for 5SY4204-7CC11?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SY4204-7CC11