Skip to main content
Siemens 5SY4210-6 — 2-Pole MCB (DIN Rail)

Siemens 5SY4210-6 SENTRON MCB, 2P B-Curve, 10 kA IEC, 20 kA

MPN5SY4210-6
Active

Siemens SENTRON 5SY4210-6, 2-pole miniature circuit breaker, B-curve, 10 kA (IEC 60898-1) / 20 kA (IEC 60947-2), 400 V AC, 60 V DC, 2 MW, IP20.

$20.32Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4210-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4210-6 — Electrical
ParameterValue
Number of poles2
5SY4210-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY4210-6 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4210-6 — Environmental
ParameterValue
Pollution degree3
5SY4210-6 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value440 V
Energy Limitation Class3

Product details

Siemens 5SY4210-6 SENTRON MCB — 2-Pole B-Curve, Dual-Rated Breaking Capacity

It is rated for 10 kA breaking capacity per IEC 60898-1 and 20 kA per IEC 60947-2, meaning it can safely interrupt fault currents up to 20 kA in industrial panel applications where the higher standard applies. The 400 V AC rating covers most three-phase distribution, while the 60 V DC rating (72 V max) handles control-circuit protection. This is a current-production part — no lifecycle concerns for a BOM freeze.

Don't use it for motor-starting duty where D-curve is needed. The dual breaking capacity (10 kA per IEC 60898-1, 20 kA per IEC 60947-2) means this breaker meets both residential and industrial standards; the 20 kA figure is the one that matters for a 400 V industrial panel with high fault current available. The DC rating of 15 kA per IEC 60947-2 covers DC distribution up to 72 V. The quick-assembly system and any-position mounting simplify panel layout.

Standards and Approvals — What They Certify

This MCB carries approvals under IEC 60898-1 (household-type MCB), IEC 60947-2 (industrial circuit-breaker standard), and UL 1077 / CSA C22.2 No. 235 (supplementary protectors for North America). The UL 1077 rating is 5 kA at AC — that's the supplementary protector rating, not the full branch-circuit rating. Halogen-free and silicon-free construction means no corrosive off-gassing in a sealed enclosure.

Frequently asked questions

What is the breaking capacity of the 5SY4210-6?

10 kA per IEC 60898-1, 20 kA per IEC 60947-2 at 400 V AC, and 15 kA per IEC 60947-2 at DC up to 72 V. Under UL 1077 it is rated 5 kA.

What is the tripping curve of the 5SY4210-6?

B-curve, which trips at 3 to 5 times rated current. Suitable for resistive and general-purpose loads, not motor starting.

Where can I buy the 5SY4210-6 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY4210-6