Siemens 5SY4210-8CC — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SY4210-8CC MCB, 10A D-curve, 2-pole, 10kA

MPN5SY4210-8CC

Siemens SENTRON miniature circuit breaker, 5SY4210-8CC, 2-pole, 10 A rated current at AC, D tripping characteristic, 10 kA breaking capacity per EN 60898, 50/60 Hz, 440 V rated voltage.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4210-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4210-8CC — Electrical
ParameterValue
Number of poles2
5SY4210-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4210-8CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4210-8CC — Environmental
ParameterValue
Pollution degree3

Product details

What the ratings mean for the panel

The 5SY4210-8CC is a Siemens SENTRON miniature circuit breaker (MCB) with a D tripping characteristic, rated 10 A at AC and 10 kA breaking capacity per EN 60898. The D curve means it tolerates high inrush currents — typically 10 to 20 times the rated current — making it the right choice for motor circuits, transformers, or welding equipment where the start-up surge would nuisance-trip a B or C curve breaker. The 10 kA breaking capacity at 400 V ensures it safely interrupts a fault up to that level without cascading upstream, which is critical for selectivity in a distribution panel. Rated voltage is 440 V AC, 50/60 Hz, and the breaker is 2-pole (switches both line conductors). The 2-module-width housing (36 mm per module) snaps onto a DIN rail and fits standard SENTRON distribution boards. Operating temperature range is -40 °C to 75 °C, with a derating curve: at 40 °C the continuous current drops to 9.19 A, at 50 °C to 8.29 A, and at 55 °C to 7.81 A. In a warm enclosure, size the load accordingly or allow ventilation.

Integration and compliance

Mounts in any position on a DIN rail via the quick-assembly system. Depth is 76 mm, which leaves clearance behind a standard 80 mm deep enclosure. The IP20 rating (with connected conductors) means it is suitable for installation inside a closed panel, not for wet or dusty environments. Pollution degree 3 and overvoltage category III confirm it is rated for fixed industrial installations where transient overvoltages are expected. Sealable, halogen-free, and silicon-free construction. Touch protection is built in. Compliance documentation (RoHS, REACH, UL, IEC) is provided by Siemens with the product; the MCB is designed to EN 60898 and carries the relevant markings.

Frequently asked questions

How do I get current pricing and availability for 5SY4210-8CC?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time; the part is sourced to order through independent distribution.

Will 5SY4210-8CC drop into a panel specified around 5SY7210-7CC without rewiring?

No. The 5SY4210-8CC is a 2-pole breaker (2 modules wide), while the 5SY7210-7CC is a 1-pole breaker (1 module). The panel would need a wider DIN-rail slot and rewiring of the second phase or neutral. The depth (76 mm) and mounting method are the same, so the mechanical fit in depth is fine, but the footprint and wiring differ.

What compliance documentation does Siemens provide for 5SY4210-8CC?

Siemens provides RoHS, REACH, and UL/IEC compliance documentation with the product. The MCB is designed to EN 60898 and carries the relevant markings for CE and UKCA where applicable.

MPN
5SY4210-8CC