Skip to main content
Siemens 5SY4210-8CC11 — 2-Pole MCB (DIN Rail)

Siemens 5SY4210-8CC11 SENTRON MCB, 2P D 10A, 400V AC, 10kA,

MPN5SY4210-8CC11

Siemens SENTRON 5SY4210-8CC11, miniature circuit breaker, 2-pole, D tripping characteristic, 10 A rated current, 400 V AC, 10 kA breaking capacity per EN 60898, designed for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4210-8CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4210-8CC11 — Electrical
ParameterValue
Number of poles2
5SY4210-8CC11 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4210-8CC11 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4210-8CC11 — Environmental
ParameterValue
Pollution degree3
5SY4210-8CC11 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value440 V

Product details

The D-curve means the magnetic trip fires between 100 A and 200 A (10–20× In), so it won't nuisance-trip on the inrush of a 10 A-rated transformer or a bank of contactor coils. The IP20 rating applies only with connected conductors — the terminals themselves are finger-safe once wired.

At 2 MW (36 mm wide), it occupies two 18 mm modular spaces. Halogen-free and silicon-free construction — important for rail and aerospace applications where outgassing can contaminate sensitive contacts or optics.

Frequently asked questions

What is the breaking capacity of the 5SY4210-8CC11?

10 kA at 400 V AC per EN 60898. That is the standard domestic/light-industrial fault level for this class of MCB.

What does the D-curve mean on this breaker?

The D tripping characteristic (10–20× In) means the magnetic trip activates between 100 A and 200 A for this 10 A breaker. It is designed for loads with high inrush current, such as transformers, welding equipment, and motor drives.

Is the 5SY4210-8CC11 suitable for railway applications?

Yes, it is explicitly designed for railway applications, with vibration resistance to IEC 60068-2-6 (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz) and an operating temperature range of -40 °C to 75 °C.

Where can I buy the 5SY4210-8CC11?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN