Siemens 5SY4213-6KK11 — 2-Pole MCB (DIN Rail)

Siemens 5SY4213-6KK11 SENTRON MCB, 2P B 13A 10kA

MPN5SY4213-6KK11

Siemens SENTRON 5SY4213-6KK11, 2-pole miniature circuit breaker, B tripping characteristic, 13 A rated current, 400 V AC, 10 kA breaking capacity per EN 60898, 20 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4213-6KK11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4213-6KK11 — Electrical
ParameterValue
Number of poles2
5SY4213-6KK11 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY4213-6KK11 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

Siemens 5SY4213-6KK11 — SENTRON 2P B-Curve MCB, 13 A

The Siemens 5SY4213-6KK11 is a 2-pole miniature circuit breaker from the SENTRON series, designed for 400 V AC systems with a B tripping characteristic and a 13 A rated current. Its 10 kA breaking capacity per EN 60898 covers standard residential and commercial branch circuits; the 20 kA rating per IEC 60947-2 gives headroom for industrial panel coordination where higher fault currents are expected. Rated for 50/60 Hz, this MCB accepts solid or stranded conductors from 0.75 to 35 mm² at both top and combined terminals. Designed for railway applications and mechanical engineering/industry environments, it carries IP20 protection with connected conductors and an ambient temperature range of -40 to +70 °C.

The dual breaking capacity rating is the key differentiator here. At 10 kA per EN 60898 it meets the standard for most final sub-circuits. The DC rating of 15 kA per IEC 60947-2 at 72 V DC maximum covers auxiliary DC control circuits common in rail and process plants. Energy limiting class 3 means this breaker limits let-through energy effectively, reducing stress on downstream wiring and equipment during a fault.

Panel integration

The combined terminal design accepts conductors from both top and bottom, simplifying daisy-chaining in a distribution board.

Frequently asked questions

What is the breaking capacity of 5SY4213-6KK11?

10 kA per EN 60898 and 20 kA per IEC 60947-2 at 400 V AC. For DC circuits, it is rated 15 kA per IEC 60947-2 at 72 V DC maximum.

What wire sizes does 5SY4213-6KK11 accept?

Solid or stranded conductors from 0.75 to 35 mm² at both top and bottom terminals.

Where can I buy 5SY4213-6KK11?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY4213-6KK11