Skip to main content
Siemens 5SY4213-8CC11 — 2-Pole MCB (DIN Rail)

Siemens 5SY4213-8CC11 SENTRON MCB, 2P D 13A 10kA

MPN5SY4213-8CC11

Siemens SENTRON 5SY4213-8CC11, 2-pole miniature circuit breaker, D tripping characteristic, 13 A rated current (AC, 35 °C), 10 kA breaking capacity per EN 60898, 2 MW width (36 mm), IP20 with connected conductors.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4213-8CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4213-8CC11 — Electrical
ParameterValue
Number of poles2
5SY4213-8CC11 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4213-8CC11 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4213-8CC11 — Environmental
ParameterValue
Pollution degree3

Product details

Siemens 5SY4213-8CC11 — D-curve MCB for high-inrush loads

The Siemens 5SY4213-8CC11 is a SENTRON miniature circuit breaker, 2-pole, D-characteristic, rated 13 A at 35 °C AC with a 10 kA breaking capacity per EN 60898. D-curve means it tolerates the inrush of motor starters, transformers, and other inductive loads without nuisance tripping — the magnetic trip fires at 10–20× rated current, not the 5–10× of a C-curve. That makes this the right choice for mechanical engineering and industrial panels where the load isn't purely resistive. The 2-pole design (2P) switches both phase conductors; there's no neutral pole integrated.

The 13 A rating holds at 35 °C ambient. Above that, the bimetallic strip trips earlier — the datasheet gives the derated values: 11.95 A at 40 °C, 11.38 A at 45 °C, 10.78 A at 50 °C, 10.15 A at 55 °C, and 9.48 A at 60 °C. If your enclosure runs hot (say 50 °C inside a sealed panel), you're effectively buying a 10.78 A breaker. Plan the load accordingly — don't size to the 35 °C figure unless you've got active cooling. Installation depth is 70 mm, total depth 76 mm.

Frequently asked questions

Where can I buy 5SY4213-8CC11 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request with your target quantity and delivery timeline; availability and pricing are confirmed at quote time.

What is the difference between 5SY4213-8CC11 and 5SY7210-7CC?

The 5SY7210-7CC is a different pole/current configuration in the same SENTRON family. The 5SY4213-8CC11 is a 2-pole, 13 A, D-curve breaker; the 5SY7210-7CC is a different variant. They share the same DIN-rail footprint and terminal design, so panel layout is compatible, but the electrical ratings differ — verify the load requirement before substituting.

What is the depth of 5SY4213-8CC11?

The total depth is 76 mm, with an installation depth of 70 mm (the portion that sits inside the enclosure behind the DIN rail).

What is the width of 5SY4213-8CC11?

36 mm, which corresponds to 2 modular width units (MW) on standard DIN-rail mounting.

What compliance documentation does Siemens provide for 5SY4213-8CC11?

The breaker carries a 10 kA breaking capacity certified per EN 60898. It is designed for overvoltage category III and pollution degree 3 per IEC 60947. The product is halogen-free and silicon-free. For specific RoHS/REACH/UL declarations, refer to the manufacturer's documentation available at the time of order.

MPN
5SY4213-8CC11