Skip to main content
Siemens 5SY4215-7CC — 2-Pole MCB (DIN Rail)

Siemens 5SY4215-7CC SENTRON MCB, C-curve 1.6 A 10 kA

MPN5SY4215-7CC

Siemens SENTRON 5SY4215-7CC, miniature circuit breaker, 2-pole, C-curve, 1.6 A rated at 35 °C, 10 kA breaking capacity per EN 60898, 50/60 Hz, IP20, 36 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4215-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4215-7CC — Electrical
ParameterValue
Number of poles2
5SY4215-7CC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY4215-7CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4215-7CC — Environmental
ParameterValue
Pollution degree3
5SY4215-7CC — Specifications
ParameterValue
Energy Limitation Class3

Product details

Miniature circuit breaker for panel protection

The Siemens SENTRON 5SY4215-7CC is a 2-pole miniature circuit breaker (MCB) with a C-curve tripping characteristic, rated 1.6 A at 35 °C (AC) and a breaking capacity of 10 kA per EN 60898. It snaps onto DIN rail, takes two modular width units (36 mm wide), and fits any mounting position. The 10 kA SCCR at 400 V means it safely interrupts faults up to that level without cascading upstream — a solid choice for final subcircuit protection in industrial control panels.

What the ratings mean for your BOM

The C-curve means magnetic trip between 5 and 10 times In — it's the standard for moderate inrush loads like small motors, contactor coils, and lighting banks. The 1.6 A rating at 35 °C derates to 1.5 A at 40 °C, 1.45 A at 45 °C, 1.4 A at 50 °C, and 1.35 A at 55 °C. If your panel ambient runs warm, size up one frame. The 10 kA breaking capacity per EN 60898 is the interrupting rating at the rated voltage — adequate for most distribution boards fed by a transformer or upstream MCCB.

Panel integration notes

Width 36 mm (2 modular units), depth 76 mm, height 90 mm. Snaps onto DIN rail via the quick-assembly system — no tools needed. Installation depth 70 mm behind the panel face. IP20 with connected conductors — fine for enclosed distribution boards, not for wet areas. Operating temperature range -40 to 75 °C with humidity limits per: max 95% RH up to 55 °C, derating to 55% at 70 °C and 35% at 75 °C. Pollution degree 3, overvoltage category III — suitable for fixed installations downstream of the main distribution.

Frequently asked questions

How do I get current pricing and availability for 5SY4215-7CC?

We source this part to order against an RFQ. Submit a request and we'll confirm availability and current pricing at quote time — no stock figures published here.

Will 5SY4215-7CC drop into a panel that was specified around 5SY4140-7 without rewiring?

Yes, the 5SY4215-7CC shares the same mechanical footprint: 36 mm width (2 modular units), 76 mm depth, 90 mm height. Same DIN-rail mounting, same terminal layout — no rewiring needed for the swap.

What is 5SY4215-7CC's rated breaking capacity?

10 kA per EN 60898 at the rated AC voltage — that's the interrupting rating for fault clearing. Adequate for most final subcircuits in industrial panels.

What compliance documentation does Siemens provide for 5SY4215-7CC?

The MCB carries the SENTRON brand and is designed per EN 60898 (breaking capacity) and IEC 81346-2 (product designation F). RoHS, REACH, and UL documentation are typically available from Siemens — contact us with your specific compliance needs and we'll source the certificates.

MPN
5SY4215-7CC