Siemens 5SY4215-8CC — 2-Pole MCB (DIN Rail)

Siemens 5SY4215-8CC SENTRON MCB, 1.6 A D-curve, 2-pole, 10 k

MPN5SY4215-8CC

Siemens SENTRON 5SY4215-8CC, miniature circuit breaker, 2-pole, D characteristic, 1.6 A rated current, 10 kA breaking capacity per EN 60898, 440 V AC, 2 MW units, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4215-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4215-8CC — Electrical
ParameterValue
Number of poles2
5SY4215-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4215-8CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4215-8CC — Environmental
ParameterValue
Pollution degree3

Product details

Siemens SENTRON 5SY4215-8CC — 1.6 A D-curve MCB, 2-pole

The Siemens SENTRON 5SY4215-8CC is a 2-pole miniature circuit breaker with a D tripping characteristic, rated 1.6 A at 35 °C and 440 V AC for multi-phase operation. The D-curve means it tolerates high inrush currents — typical for motor, transformer, or lighting ballast loads — without nuisance tripping, while still clearing a fault at its 10 kA breaking capacity per EN 60898. That 10 kA rating at 440 V AC tells you it safely interrupts a short-circuit up to that level without upstream damage, which is the spec that governs coordination in a distribution board.

Thermal derating and environmental limits

Rated current drops with ambient temperature: 1.6 A at 35 °C, 1.5 A at 40 °C, 1.45 A at 45 °C, 1.4 A at 50 °C, 1.35 A at 55 °C. The surrounding temperature influence curve caps at 95% RH up to 55 °C, then 55% RH up to 70 °C, then 35% RH up to 75 °C. Operating range spans -40 °C to 75 °C, so it handles unheated outdoor cabinets or hot machine enclosures. Pollution degree 3 and overvoltage category III suit industrial panel environments.

Mounting and wiring notes

Snaps onto DIN rail via the quick-assembly system; any mounting position allowed. Combined terminals top and bottom accept wiring without extra accessories. Installation depth is 70 mm (device depth 76 mm). IP20 with connected conductors — standard for enclosed distribution boards. Halogen-free and silicon-free construction matters for environments sensitive to outgassing (clean rooms, food processing). Touch protection is built in.

Frequently asked questions

Where can I buy 5SY4215-8CC and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SY4215-8CC?

The breaking capacity is 10 kA per EN 60898 at 440 V AC multi-phase operation.

MPN
5SY4215-8CC