Skip to main content
Siemens 5SY4220-7CC11 — 2-Pole MCB (DIN Rail)

Siemens 5SY4220-7CC11 SENTRON MCB, 2-Pole C-Curve, 10 kA

MPN5SY4220-7CC11

Siemens SENTRON 5SY4220-7CC11, miniature circuit breaker, 2-pole, C-curve, 10 kA breaking capacity per EN 60898, 400 V AC, 2 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4220-7CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4220-7CC11 — Electrical
ParameterValue
Number of poles2
5SY4220-7CC11 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY4220-7CC11 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4220-7CC11 — Environmental
ParameterValue
Pollution degree3
5SY4220-7CC11 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value440 V
Energy Limitation Class3

Product details

Siemens 5SY4220-7CC11 — 2-Pole C-Curve MCB, 10 kA, Current Production

The Siemens 5SY4220-7CC11 is a SENTRON miniature circuit breaker (MCB) in a 2-pole configuration, rated for 400 V AC with a C-curve tripping characteristic. Its 10 kA breaking capacity per EN 60898 means it can safely interrupt fault currents up to 10,000 A under standard test conditions — sufficient for most industrial distribution panels where the prospective short-circuit current stays within that limit. The C-curve (5–10× In) is the standard choice for moderate inrush loads like small motors, transformers, and lighting circuits; it avoids nuisance tripping on startup while still clearing fast on a hard fault. Designed for railway applications per the evidence, the breaker also carries a pollution degree 3 rating and overvoltage category III, meaning it's built for environments with conductive pollution (condensation, light dust) and for fixed installations downstream of the main distribution board. The 2-pole design switches both phase conductors but does not switch the neutral.

Mounting and Panel Fit

Occupies 2 modular width units (36 mm total width) on a standard DIN rail. Depth is 76 mm; installation depth behind the panel face is 70 mm. The quick-assembly fastening system means it snaps onto the rail without tools and can be mounted in any position. For a panel OEM planning fill factor: at 36 mm wide, 10 breakers fit per 360 mm of rail, leaving room for end clamps. The combined terminals at top and bottom accept both busbar and conductor connections without re-termination. IP20 with connected conductors — suitable for enclosed distribution boards; not rated for washdown or outdoor exposure without a secondary enclosure. The sealable feature allows a lead seal or tag to be fitted through the breaker housing, meeting some utility or railway requirements for tamper evidence.

MPN
5SY4220-7CC11