Skip to main content
Siemens 5SY4232-6CC — 2-Pole MCB (DIN Rail)

Siemens 5SY4232-6CC SENTRON MCB, 32 A, B-Curve, 2-Pole, 10 k

MPN5SY4232-6CC

Siemens SENTRON 5SY4 series, 5SY4232-6CC miniature circuit breaker, 2-pole, B-curve, 32 A, 10 kA breaking capacity per EN 60898, 400 V AC, 2 width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4232-6CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4232-6CC — Electrical
ParameterValue
Number of poles2
5SY4232-6CC — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY4232-6CC — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4232-6CC — Environmental
ParameterValue
Pollution degree3

Product details

Siemens 5SY4232-6CC — 32 A B-Curve MCB, Current Production

The Siemens 5SY4232-6CC is a SENTRON miniature circuit breaker rated 32 A with a B-curve tripping characteristic, 2-pole construction, and a 10 kA breaking capacity per EN 60898 at 400 V AC. It also carries a 5 kA rating per UL 1077 and CSA C22.2 No. 235, so it qualifies for North American panel builds that accept supplementary protectors.

Panel Fit & Integration — 36 mm Wide, 2 Width Units

At 36 mm wide (2 width units on a standard DIN rail), the 5SY4232-6CC occupies two 18 mm slots in a distribution board. The combined terminal at top and bottom accepts the same conductor size, so wiring order doesn't matter.

Environmental & Compliance — Halogen-Free, Wide Temperature Range

Halogen-free and silicon-free construction — important for installations where off-gassing from a fault could damage nearby electronics or where silicone contamination affects contactors or drives.

DC Capability & Selectivity Notes

Rated for DC operation up to 72 V maximum — useful for control-circuit protection in 48 V or 60 V DC systems, but not a 125 V DC rail. In a selectivity study, the B-curve coordinates well with upstream SENTRON S-class or NH fuses for lighting and general distribution.

Frequently asked questions

Where can I buy 5SY4232-6CC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SY4232-6CC?

10 kA per EN 60898 at 400 V AC, and 5 kA per UL 1077 and CSA C22.2 No. 235.

What is the difference between 5SY4232-6CC and 5SY3132-6?

The 5SY3132-6 is a 1-pole version of the same 32 A B-curve MCB. The 5SY4232-6CC is 2-pole, so it switches both line and neutral (or two phases) in a single unit. You cannot drop a 2-pole into a panel wired for a 1-pole without rewiring the busbar and neutral arrangement.

MPN
5SY4232-6CC