Skip to main content
Siemens 5SY4240-8 — 2-Pole MCB (DIN Rail)

Siemens 5SY4240-8 SENTRON MCB, D Curve, 2P, 400V

MPN5SY4240-8
Active

Siemens SENTRON 5SY4240-8, D-curve miniature circuit breaker, 2-pole, 400 V AC / 72 V DC, 10 kA per EN 60898-1, 15 kA per IEC 60947-2.

$169.84Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4240-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4240-8 — Electrical
ParameterValue
Number of poles2
5SY4240-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4240-8 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4240-8 — Environmental
ParameterValue
Pollution degree3
5SY4240-8 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value440 V

Product details

The 5SY4240-8: The breaker occupies 2 modular width units (36 mm) with a 70 mm installation depth (76 mm overall depth for finger-safe terminals). Panel designers can count on a compact footprint for DIN-rail layouts, and the quick-assembly system speeds mounting.

Acceptable in any mounting position. Ambient range from -40 °C to 75 °C covers most indoor enclosures, with relative humidity limits decreasing above 55 °C (95 % RH at 55 °C down to 35 % at 75 °C). Vibration resistance per IEC 60068-2-6: 5 to 25 Hz at ±1 mm, 25 to 150 Hz at 50 m/s², so it holds up in machine-tool panels. Sealable terminals allow lockout/tagout compliance.

Designed to IEC/EN 60898-1 and IEC/EN 60947-2, with UL 1077 recognition for the AC rating (5 kA per UL 1077). Combined terminal top and bottom accept standard busbar or wire connections, with neutral conductor switching not integrated (external switching required for full isolation).

Frequently asked questions

What standards does the 5SY4240-8 comply with?

The breaker is designed to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077. It is also halogen-free and silicon-free, suitable for applications requiring those material restrictions.

What are the physical dimensions of the 5SY4240-8?

Width is 36 mm (2 modular width units), height is 90 mm, overall depth is 76 mm, and installation depth is 70 mm.

MPN
5SY4240-8