Skip to main content
Siemens 5SY4260-7 — 2-Pole MCB (DIN Rail)

Siemens 5SY4260-7 SENTRON MCB, 2P C-Curve, 10kA IEC/EN 60898

MPN5SY4260-7
Active

Siemens SENTRON 5SY4260-7, 2-pole miniature circuit breaker, C-curve, 10 kA (EN 60898-1) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 2 MW units, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4260-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4260-7 — Electrical
ParameterValue
Number of poles2
5SY4260-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY4260-7 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4260-7 — Environmental
ParameterValue
Pollution degree3
5SY4260-7 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value440 V
Energy Limitation Class3

Product details

The Siemens 5SY4260-7 is a SENTRON 2-pole miniature circuit breaker with a C-curve trip characteristic, rated 10 kA breaking capacity per EN 60898-1 and 15 kA per IEC 60947-2 at 400 V AC. It also carries a 15 kA DC rating at 60 V (72 V max) per IEC 60947-2, and 5 kA per UL 1077.

The 76 mm depth (70 mm installation depth) leaves clearance for standard 80 mm deep enclosures. IP20 with connected conductors; suitable for panel environments, not washdown zones.

Environmental range

Rated for -40 °C to 75 °C ambient, with humidity derating: 95% RH up to 55 °C, 55% RH up to 70 °C, 35% RH up to 75 °C. Mount in any position. Sealable to prevent tamper — useful for metering or critical circuits.

Frequently asked questions

What are the key ratings of 5SY4260-7?

2-pole, C-curve, 10 kA per EN 60898-1, 15 kA per IEC 60947-2 at 400 V AC, 15 kA at 60 V DC. Rated 400 V AC (440 V max multi- or single-phase), 60 V DC (72 V max).

Will 5SY4260-7 drop into a panel specified for 5SY4140-7?

Yes — both are 2-pole SENTRON MCBs with the same 36 mm width (2 MW), same DIN-rail mounting, same depth. The difference is the trip curve: 5SY4140-7 is a B-curve (3–5× In) for resistive/light loads; 5SY4260-7 is a C-curve (5–10× In) for motor or moderate-inrush circuits. No rewiring needed if the panel was laid out for a 2-pole SENTRON.

Where can I buy 5SY4260-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
5SY4260-7