Siemens 5SY4302-6CC — 3-Pole MCB (DIN Rail)

Siemens 5SY4302-6CC SENTRON MCB, 3P B-Curve 2A 10kA

MPN5SY4302-6CC

Siemens SENTRON 5SY4302-6CC, 3-pole miniature circuit breaker, B-curve, 2 A rated, 10 kA breaking capacity at 440 V AC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4302-6CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4302-6CC — Protection
ParameterValue
Tripping characteristic (curve)B
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4302-6CC — Electrical
ParameterValue
Rated current (AC)2 A
Rated voltage (AC, multi-phase)440 V
Neutral conductor switchingNo
5SY4302-6CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
5SY4302-6CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

What this MCB is and where it fits

The Siemens 5SY4302-6CC is a SENTRON miniature circuit breaker — a 3-pole, B-curve unit rated 2 A at AC with a 10 kA breaking capacity per EN 60898. It's designed for DIN-rail mounting in distribution boards and control panels, protecting branch circuits against overload and short-circuit in commercial and industrial installations. The B-curve characteristic (3–5× In) makes it a good fit for resistive and general-purpose loads where inrush is moderate — lighting, small transformers, or control circuits.

Key ratings — what they mean for your panel

Rated current is 2 A at 35 °C, derated to 1.91 A at 40 °C and 1.75 A at 55 °C — so if your enclosure runs warm, factor the thermal derating into your load budget. The 10 kA breaking capacity at 440 V AC (multi-phase operation) is the maximum fault current this breaker can safely interrupt; that's sufficient for most secondary distribution panels but should be checked against the available fault current at the installation point. Overvoltage category III means it's rated for fixed-installation use downstream of the main service entrance. The 50/60 Hz rating covers both standard line frequencies.

Mounting and integration notes

Occupies 3 modular width units (54 mm total) on a DIN rail. Depth is 76 mm, installation depth 70 mm — verify clearance in your enclosure before committing. Mounting position is any, so vertical or horizontal rail orientation works. Combined terminals top and bottom accept conductors for straightforward daisy-chaining. IP20 with connected conductors — suitable for dry indoor panels only, not washdown or outdoor locations.

Frequently asked questions

What is the breaking capacity of 5SY4302-6CC?

10 kA per EN 60898 at 440 V AC in multi-phase operation.

What temperature range does 5SY4302-6CC handle?

Operating ambient range is -40 °C to 75 °C, with derating above 35 °C as listed in the spec table.

Where can I buy 5SY4302-6CC and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN