Siemens 5SY4303-7 — 3-Pole MCB (DIN Rail)

Siemens 5SY4303-7 3-Pole MCB DIN Rail, C-Curve, 10 kA

MPN5SY4303-7
Active

Siemens SENTRON 5SY4303-7, 3-pole miniature circuit breaker, C-trip characteristic, 10 kA breaking capacity per EN 60898, 35 kA per IEC 60947-2, 400 V AC, 60 V DC.

$230.57Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4303-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4303-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-235 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4303-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.3 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4303-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4303-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

The 5SY4303-7 carries a dual-rated breaking capacity: 10 kA per EN 60898 at 400 V AC, and 35 kA per IEC 60947-2 — the higher figure applies when the MCB is installed in an industrial distribution board where the prospective fault current exceeds 10 kA, provided the upstream transformer and cable impedance allow it. C-trip characteristic means the magnetic release picks up between 5× and 10× In — the right choice for motor-starter or transformer primary protection where inrush current would nuisance-trip a B-curve device, but still fast enough to clear a bolted fault before the downstream contactor welds shut.

AC and DC voltage envelope

Rated 400 V AC for multi-phase operation, 440 V AC for both multi-phase and single-phase operation — the 40 V headroom above the nominal 400 V line accounts for the steady-state voltage rise on a lightly loaded transformer secondary. DC rating is 60 V per pole, with a maximum operating voltage of 72 V DC — the 12 V margin above the nominal rating is the ceiling before the arc-extinction gap in a single-pole DC break becomes unreliable.

Lifecycle and sourcing — active, quoted to order

Current-production status (lifecycle stage: current). No successor or phase-out notice on record — the 5SY4303-7 is the standard catalogue variant for the 3-pole C-curve 10 kA position in the SENTRON family.

IP20 with connected conductors — the terminals are finger-safe when wired, but the enclosure does not seal against water ingress. Sealable (padlockable) handle for lockout/tagout compliance. Ambient temperature range -40 °C to 75 °C, with humidity derating above 55 °C: max 95% RH at 55 °C, falling to 35% RH at 75 °C.

MPN
5SY4303-7