Skip to main content
Siemens 5SY4304-7 — 3-Pole MCB (DIN Rail)

Siemens 5SY4304-7 SENTRON MCB, 3-Pole C-Curve, 10 kA

MPN5SY4304-7
Active

Siemens SENTRON 5SY4304-7, 3-pole miniature circuit breaker, C characteristic, 10 kA (EN 60898), 35 kA (IEC 60947-2), 400 V AC, IP20.

$25.77Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4304-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4304-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-235 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4304-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.3 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4304-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4304-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

The Siemens SENTRON 5SY4304-7 is a 3-pole miniature circuit breaker with a C tripping characteristic, rated 10 kA interrupting capacity per EN 60898 and 35 kA per IEC 60947-2 at 400 V AC. It also carries a 5 kA rating under UL 1077 and a 15 kA DC rating per IEC 60947-2 at 60 V DC. This dual-standard rating means it can serve in IEC-based distribution panels and, with the UL 1077 listing, in North American supplementary protection applications — a useful overlap for multi-region machine builds.

The 10 kA rating at 400 V AC (EN 60898) is the standard domestic/commercial fault level; the 35 kA rating (IEC 60947-2) covers industrial panels where the prospective short-circuit current is higher. The 15 kA DC rating at 60 V DC means it can also protect DC bus circuits in drives or solar combiners, provided the voltage stays under 72 V DC. The 3-module width (54 mm,) and 76 mm depth fit standard DIN-rail enclosures; the quick-assembly fastening and any-position mounting simplify panel layout.

Frequently asked questions

What compliance documentation does the 5SY4304-7 carry?

It is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077. It is halogen-free and silicon-free.

MPN