Skip to main content
Siemens 5SY4304-7CV — 3-Pole MCB (DIN Rail)

Siemens 5SY4304-7CV MCB, 3P C4, 15 kA at 400 V AC

MPN5SY4304-7CV

Siemens 5SY4304-7CV, 3-pole miniature circuit breaker, C-curve, 4 A rated, 15 kA breaking capacity at 400 V AC, IEC 60947-2, IP20 with conductors connected.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4304-7CV — Identification
ParameterValue
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4304-7CV — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-215 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY4304-7CV — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Power loss per pole at rated current (AC, hot)1.3 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
5SY4304-7CV — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4304-7CV — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

Siemens 5SY4304-7CV — 3-pole C4 MCB for industrial panel protection

The Siemens 5SY4304-7CV is a 3-pole miniature circuit breaker with a C-curve trip characteristic, rated 4 A and a 15 kA breaking capacity at 400 V AC per IEC 60947-2. It is designed for mechanical engineering and industrial panel applications, protecting branch circuits against overload and short-circuit faults. DC operation is limited to 72 V maximum, so this is an AC-primary device — do not spec it for a DC bus above that voltage.

For a BOM freeze or line-down replacement, this part is a direct drop-in fit for any panel specified with the Siemens 5SY4 series 3-pole C-curve breakers. No rewiring or busbar rework needed if the existing breaker is the same pole count and form factor.

Sealable — lockable with a padlock for lockout/tagout compliance. In a densely packed enclosure, account for this self-heating; the breaker's own derating curve (95 % at 55 °C, 55 % at 70 °C, 35 % at 75 °C) governs the actual continuous current you can pull.

Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. Mechanical service life typical 10,000 operating cycles — sufficient for most industrial switching duties where the breaker is cycled infrequently (maintenance isolation, not daily load switching). Degree of pollution 3, overvoltage category III — suitable for fixed industrial installations where conductive pollution or condensation may occur.

Frequently asked questions

What is the breaking capacity of 5SY4304-7CV?

15 kA at 400 V AC per IEC 60947-2. This is the rated ultimate short-circuit breaking capacity (Icu) for the 3-pole configuration.

Will 5SY4304-7CV drop into a panel specified for 5SY4310-7CV?

Yes — same 3-pole footprint, same DIN-rail mounting, same 54 mm width and 76 mm depth. The only difference is the current rating: 4 A vs 10 A. No rewiring or busbar change needed if the panel was designed for the 5SY4 3-pole form factor.

Where can I buy 5SY4304-7CV?

Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY4304-7CV