Skip to main content
Siemens 5SY4306-7CC11 — 3-Pole MCB (DIN Rail)

Siemens 5SY4306-7CC11 SENTRON MCB, 3P C-Characteristic, 10 k

MPN5SY4306-7CC11

Siemens SENTRON 5SY4306-7CC11 miniature circuit breaker, 3-pole, tripping characteristic C, 10 kA breaking capacity at 400 V AC per EN 60898, 3 MW, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4306-7CC11 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4306-7CC11 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4306-7CC11 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.2 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4306-7CC11 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4306-7CC11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

Siemens SENTRON 5SY4306-7CC11 — 3-pole MCB, C-curve, 10 kA

The Siemens 5SY4306-7CC11 is a 3-pole miniature circuit breaker from the SENTRON series, designed with tripping characteristic C and a breaking capacity of 10 kA at 400 V AC per EN 60898.

Railway-rated construction and environmental tolerance

This MCB carries a design-for-railway-applications designation, meaning it meets the vibration resistance of IEC 60068-2-6: ±1 mm at 5 to 25 Hz and 50 m/s² at 25 to 150 Hz. It operates across -40 °C to 75 °C, with humidity tolerance up to 95% at 55 °C, derating to 35% at 75 °C.

Panel integration and compliance notes

Installation depth is 70 mm, with a total depth of 76 mm including the front. The neutral conductor is not switched (3-pole only).

Frequently asked questions

What is the breaking capacity of 5SY4306-7CC11?

10 kA at 400 V AC per EN 60898. It also carries a 440 V AC rating for single-phase and multi-phase operation.

What does tripping characteristic C mean for this MCB?

The C-curve trips between 5 and 10 times rated current, making it suitable for moderate inrush loads like motor starters and small transformers in industrial panels.

Where can I buy 5SY4306-7CC11 and how is it quoted?

This part is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What compliance documentation is available for 5SY4306-7CC11?

The MCB is halogen-free and silicon-free. It meets IEC 60068-2-6 vibration resistance, pollution degree 3, and overvoltage category III. Standard Siemens SENTRON documentation (CE, UKCA, EAC) applies; specific RoHS/REACH declarations are available on request.

MPN