Skip to main content
Siemens 5SY4306-8CC — 3-Pole MCB (DIN Rail)

Siemens 5SY4306-8CC SENTRON MCB, 3P D-curve 6A, 10kA

MPN5SY4306-8CC

Siemens SENTRON, miniature circuit breaker, 5SY4306-8CC, 3-pole, D characteristic, 6 A rated current, 10 kA breaking capacity per EN 60898.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4306-8CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4306-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 6089810 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY4306-8CC — Electrical
ParameterValue
Rated current (AC)6 A
Rated voltage (AC, multi-phase)440 V
5SY4306-8CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
5SY4306-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

What the ratings mean for your panel

The Siemens 5SY4306-8CC is a SENTRON miniature circuit breaker — 3-pole, D tripping characteristic, rated 6 A at AC. The D curve means it tolerates high inrush currents (typically 10–20× rated), so it's the right choice for motor starters, transformers, or power supplies that pull a heavy surge on energization. The 10 kA breaking capacity per EN 60898 tells you it can safely interrupt a fault current up to that level without welding contacts or cascading upstream — essential for coordination in a distribution board. Under UL 1077 the same part carries a 5 kA interrupting rating, so verify which standard governs your installation.

Mounting and integration

Snaps onto DIN rail via the quick-assembly system; occupies 3 modular width units (54 mm). Depth is 76 mm, installation depth 70 mm — fits standard distribution enclosures without crowding the gland plate. Mounting position is any; IP20 with connected conductors means it's for dry indoor panels only, not washdown areas. Terminal top and bottom are combined (busbar-friendly), and the design is halogen-free and silicon-free — relevant for clean-room or corrosive-environment specs.

Thermal derating and environment

Rated 6 A at 35 °C ambient; at 40 °C it derates to 5.51 A, at 50 °C to 4.97 A, and at 55 °C to 4.69 A. If your panel runs hot (say 50 °C inside), size the load to stay under 5 A per pole. Operating range is -40 °C to 75 °C, with humidity limits: max 95% up to 55 °C, then derating to 35% at 75 °C. Overvoltage category III and pollution degree 3 — suitable for fixed installations downstream of the main distribution board.

Frequently asked questions

What is the breaking capacity of 5SY4306-8CC?

10 kA per EN 60898, and 5 kA per UL 1077 / CSA C22.2 No. 235.

Where can I buy 5SY4306-8CC?

Sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What is the D tripping characteristic used for?

The D curve (10–20× In) handles high inrush loads like motor starters, transformers, and power supplies without nuisance tripping.

MPN
5SY4306-8CC