Skip to main content
Siemens 5SY4310-6CC — 3-Pole MCB (DIN Rail)

Siemens 5SY4310-6CC SENTRON MCB, 3P B-10A, 10 kA

MPN5SY4310-6CC

Siemens SENTRON 5SY4CC series, miniature circuit breaker, 3-pole, B-characteristic, 10 A rated, 10 kA IEC 60898, 5 kA UL 1077, 400 V AC, 3 width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4310-6CC — Identification
ParameterValue
Design / model code5SY4CC
Brand nameSENTRON
Number of poles3
Suitability for operationMechanical engineering / industry
5SY4310-6CC — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089810 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY4310-6CC — Electrical
ParameterValue
Rated current (AC)400 V
Rated voltage (AC, multi-phase)440 V
Rated frequency50/60 Hz
5SY4310-6CC — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4310-6CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens 5SY4310-6CC is a SENTRON miniature circuit breaker (MCB) in the 5SY4CC design, rated 10 A at 400 V AC with a B tripping characteristic across 3 poles. Its IEC 60898 breaking capacity is 10 kA; under UL 1077 and CSA C22.2 No. 235 it carries 5 kA — the UL figure governs installations in North American panels, while the IEC figure applies in European-distribution boards.

It mounts in any position, which simplifies layout in crowded enclosures — no derating required for horizontal or inverted orientation. The combined terminal at top and bottom accepts conductors for daisy-chaining busbars, and the sealable cover allows lockout-tagout compliance on the panel door.

Environmental and compliance profile

Rated for ambient temperatures from -40 °C to 75 °C, with humidity derating per the spec: max 95% RH up to 55 °C, dropping to 35% at 75 °C. The MCB is halogen-free and silicon-free — important for clean-room or semiconductor-adjacent panels where outgassing must be controlled.

Frequently asked questions

What is the breaking capacity of 5SY4310-6CC under UL vs IEC?

Under IEC 60898 it is rated 10 kA; under UL 1077 and CSA C22.2 No. 235 it carries 5 kA. The lower UL figure governs North American panel approvals.

What is the tripping characteristic of this MCB?

B-curve — trips between 3 and 5 times rated current (30–50 A for this 10 A unit). Suited for resistive and general-purpose loads with moderate inrush.

What compliance documentation is available for 5SY4310-6CC?

The part carries IEC 60898 and UL 1077 / CSA C22.2 No. 235 approvals. It is halogen-free and silicon-free. RoHS and REACH declarations are standard for Siemens SENTRON products; request them with the RFQ.

Where can I buy 5SY4310-6CC and how is it quoted?

Sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm line-item price.

MPN