The Siemens SENTRON 5SY4310-7CC is a 3-pole miniature circuit breaker with C-curve tripping characteristic, rated 10 kA breaking capacity at 400 V AC according to EN 60898. For UL 1077 and CSA C22.2 No. 235 applications, the interrupting rating is 5 kA. The C-curve (5–10× In) is standard for protecting inductive loads like motor circuits, contactor coils, and small transformers where inrush current exceeds resistive load levels.
5SY4310-7CC SENTRON MCB, 3P C-curve, 10 kA, 400 V
Siemens SENTRON 5SY4310-7CC, 3-pole miniature circuit breaker, tripping characteristic C, 10 kA at 400 V AC, 3 modular width units.
Specifications
| Parameter | Value |
|---|---|
| Brand name | SENTRON |
| Number of poles | 3 |
| Pole configuration | 3P |
| Suitability for operation | Mechanical engineering / industry |
| Parameter | Value |
|---|---|
| Tripping characteristic (curve) | C |
| Breaking capacity per EN 60898 | 10 kA |
| Overvoltage category | III |
| IP protection class | IP20, with connected conductors |
| Energy limitation class | 3 |
| Pollution degree | 3 |
| Parameter | Value |
|---|---|
| Rated voltage (AC, multi-phase) | 440 V |
| Voltage type (AC/DC) | AC |
| Supply frequency range | 50/60 Hz |
| Power loss per pole at rated current (AC, hot) | 1.1 W |
| Mechanical service life (operating cycles, typ.) | 10 000 |
| Neutral conductor switching | No |
| Rated voltage (AC, single-phase) | 440 V |
| Parameter | Value |
|---|---|
| Modular width units | 3 |
| Mounting position | any |
| Width | 54 mm |
| Height | 90 mm |
| Depth | 76 mm |
| Installation depth | 70 mm |
| Terminal tightening torque, max. | 75 °C |
| Terminal tightening torque, min. | -40 °C |
| Combined terminal, top | Yes |
| Combined terminal, bottom | Yes |
| Fastening method | Quick assembly system |
| Sealable | Yes |
| Accepts supplementary devices | Yes |
| Parameter | Value |
|---|---|
| Halogen-free | Yes |
| Silicone-free | Yes |
| Influence of surrounding temperature | max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C |
| Vibration resistance (IEC 60068-2-6) | ±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz |
Product details
Frequently asked questions
How do I get current pricing and availability for 5SY4310-7CC?
Submit an RFQ against this order code. Pricing and stock are confirmed at quote time through our independent distribution channels.
Will 5SY4310-7CC drop into a panel specified around 5SY4310-7CV without rewiring?
Both are 3-pole SENTRON MCBs with the same DIN-rail footprint and 3-module width. The difference is the tripping characteristic: 5SY4310-7CC is C-curve, 5SY4310-7CV is not specified here. If the panel was designed for a C-curve breaker, it fits mechanically; verify the curve matches the original spec before swapping.
What compliance documentation does Siemens provide for 5SY4310-7CC?
The part carries ratings per EN 60898 (10 kA at 400 V AC) and UL 1077 / CSA C22.2 No. 235 (5 kA). It is halogen-free and silicon-free. Standard Siemens declarations for RoHS and REACH apply; request the specific declaration of conformity with your RFQ.