Siemens SENTRON 5SY4310-7CC11 MCB, 3P C10A 10kA 400V

MPN5SY4310-7CC11

Siemens SENTRON series, miniature circuit breaker, 3-pole, C-curve, 10 A rated, 10 kA breaking capacity (EN 60898), 400 V AC, 54 x 76 x 90 mm, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4310-7CC11 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Suitability for operationMechanical engineering / industry
5SY4310-7CC11 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
5SY4310-7CC11 — Electrical
ParameterValue
Rated current (AC)400 V
Rated voltage (AC, multi-phase)440 V
Rated frequency50/60 Hz
5SY4310-7CC11 — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4310-7CC11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

Multi-phase and single-phase operation both rated at 440 V AC, so it handles line-to-line faults on 400 V systems with headroom. DC rating max 72 V — usable for DC control circuits at that voltage, but not a primary DC breaker. Overvoltage category III means it's rated for fixed-installation distribution boards, not just final circuits. Energy limiting class 3 indicates fast arc extinction, limiting let-through energy to downstream equipment. Mechanical service life typical 10 000 switching cycles. The breaker is sealable — a lockable cover or tag-out provision can be fitted for lockout/tagout compliance. Touch protection included.

Frequently asked questions

What is the breaking capacity of 5SY4310-7CC11?

10 kA per EN 60898 at 400 V AC. That's the standard breaking capacity for sub-distribution in industrial panels.

What does the C-curve mean on this MCB?

C-curve (5–10× In) means the magnetic trip activates at 50–100 A for this 10 A breaker. It's designed for moderate inrush loads like contactors, small motors, and lighting — not for purely resistive loads (B-curve) or high-inrush transformers (D-curve).

Can 5SY4310-7CC11 be used in DC circuits?