Skip to main content
Siemens 5SY4310-8CC — 3-Pole MCB (DIN Rail)

Siemens 5SY4310-8CC SENTRON MCB, 3P D 10 A, 10 kA

MPN5SY4310-8CC

Siemens SENTRON 5SY4310-8CC miniature circuit breaker, 3-pole, D tripping characteristic, 10 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4310-8CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4310-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 6089810 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY4310-8CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.9 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4310-8CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4310-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

The Siemens 5SY4310-8CC is a SENTRON miniature circuit breaker, 3-pole, D-curve, rated 10 A at 400 V AC with a 10 kA breaking capacity per EN 60898. That D characteristic means it handles high inrush currents — motor starts, transformer energization, welding equipment — without nuisance tripping on the magnetic release. The 10 kA rating at 400 V gives you selectivity headroom downstream of a larger feeder breaker in a 400 V panel.

Ratings & Compliance

Breaking capacity: 10 kA per EN 60898, 5 kA per UL 1077 and CSA C22.2 No. 235. That UL/CSA supplementary protector rating matters if the panel ships to North America — the 5 kA SCCR at 400 V is enough for most branch circuits behind a current-limiting feeder. Halogen-free and silicon-free construction meets clean-room and high-reliability specs.

Frequently asked questions

Where can I buy 5SY4310-8CC and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SY4310-8CC drop into a panel specified around 5SY6332-7CC without rewiring?

Both are 3-pole SENTRON MCBs with the same 54 mm width (3 modular units) and DIN-rail mounting, so the physical fit is identical. The difference is the tripping curve: 5SY4310-8CC is D-curve (10–20× In magnetic trip), while 5SY6332-7CC is a different characteristic — verify the load's inrush profile before swapping. No rewiring needed for the same footprint.

What compliance documentation does this brand provide for 5SY4310-8CC?

The SENTRON series carries EN 60898 (IEC) and UL 1077 / CSA C22.2 No. 235 certifications. The part is halogen-free and silicon-free, which supports RoHS/REACH compliance declarations. Specific certificates are available from the manufacturer on request.

MPN
5SY4310-8CC