Skip to main content
Siemens 5SY4310-8CC — Miniature Circuit Breakers (MCB)

Siemens 5SY4310-8CC SENTRON MCB, 3P D 10 A, 10 kA

MPN5SY4310-8CC

Siemens SENTRON 5SY4310-8CC miniature circuit breaker, 3-pole, D tripping characteristic, 10 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4310-8CC — Ratings
ParameterValue
Overvoltage categoryIII
5SY4310-8CC — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SY4310-8CC is a SENTRON miniature circuit breaker, 3-pole, D-curve, rated 10 A at 400 V AC with a 10 kA breaking capacity per EN 60898. That D characteristic means it handles high inrush currents — motor starts, transformer energization, welding equipment — without nuisance tripping on the magnetic release. The 10 kA rating at 400 V gives you selectivity headroom downstream of a larger feeder breaker in a 400 V panel.

Ratings & Compliance

Breaking capacity: 10 kA per EN 60898, 5 kA per UL 1077 and CSA C22.2 No. 235. That UL/CSA supplementary protector rating matters if the panel ships to North America — the 5 kA SCCR at 400 V is enough for most branch circuits behind a current-limiting feeder. Halogen-free and silicon-free construction meets clean-room and high-reliability specs.

Frequently asked questions

Where can I buy 5SY4310-8CC and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SY4310-8CC drop into a panel specified around 5SY6332-7CC without rewiring?

Both are 3-pole SENTRON MCBs with the same 54 mm width (3 modular units) and DIN-rail mounting, so the physical fit is identical. The difference is the tripping curve: 5SY4310-8CC is D-curve (10–20× In magnetic trip), while 5SY6332-7CC is a different characteristic — verify the load's inrush profile before swapping. No rewiring needed for the same footprint.

What compliance documentation does this brand provide for 5SY4310-8CC?

The SENTRON series carries EN 60898 (IEC) and UL 1077 / CSA C22.2 No. 235 certifications. The part is halogen-free and silicon-free, which supports RoHS/REACH compliance declarations. Specific certificates are available from the manufacturer on request.

MPN
5SY4310-8CC