Siemens 5SY4315-5 SENTRON 3-Pole MCB, 10 kA, Char. A

MPN5SY4315-5
Active

Siemens SENTRON 5SY4315-5, 3-pole miniature circuit breaker, tripping characteristic A, 10 kA breaking capacity at 400 V AC per EN 60898, 35 kA per IEC 60947-2, 54 mm wide (3 MW).

$227.17Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4315-5 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4315-5 — Protection
ParameterValue
Tripping characteristic (curve)A
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-235 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY4315-5 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)2.1 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4315-5 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4315-5 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

Certification and environmental range

Dual-rated to IEC/EN 60898-1 and IEC/EN 60947-2 / UL1077, the 5SY4315-5 carries approvals for both residential-style and industrial applications. The UL1077 listing (5 kA at AC) covers North American supplementary protection use. Rated insulation voltage is 440 V AC for both single-phase and multi-phase operation, with a DC rating of 60 V (72 V max).

Frequently asked questions

What is the breaking capacity of 5SY4315-5 at 400 V AC?

10 kA per EN 60898-1 and 35 kA per IEC 60947-2 at 400 V AC. At DC (60 V) it is rated 15 kA per IEC 60947-2.

What does tripping characteristic A mean?

Characteristic A trips magnetically at 2 to 3 times rated current. It is faster than B-curve (3-5×) and C-curve (5-10×), making it suitable for protecting sensitive loads like semiconductor circuits or long cable runs where fast fault clearing is needed.