Siemens 5SY4350-7KK11 — 3-Pole MCB (DIN Rail)

Siemens 5SY4350-7KK11 SENTRON MCB, 50A 3P C-Curve, 10kA

MPN5SY4350-7KK11

Siemens SENTRON 5SY4350-7KK11 miniature circuit breaker, 3-pole, C-curve, 50 A rated, 10 kA breaking capacity per EN 60898, 15 kA per IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY4350-7KK11 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Suitability for operationMechanical engineering / industry

Protection

5SY4350-7KK11 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-215 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3

Electrical

5SY4350-7KK11 — Electrical
ParameterValue
Rated current (AC)50 A
Rated voltage (AC, multi-phase)440 V

Mechanical

5SY4350-7KK11 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes

Environmental

5SY4350-7KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

What this MCB carries and where it fits

The Siemens 5SY4350-7KK11 is a SENTRON miniature circuit breaker rated 50 A at AC, with a C tripping characteristic that handles moderate inrush — typical for motor-starter and lighting panels in mechanical engineering and industrial environments. Three poles, 3 modular width units (54 mm wide), and a depth of 76 mm (70 mm installation depth) mean it occupies standard DIN-rail space; the quick-assembly fastening and any mounting position let a wireman slot it into a crowded gland plate without rework. Pollution degree 3 and overvoltage category III suit it for fixed installations inside a panel where the environment isn't climate-controlled.

Breaking capacity and temperature derating

Rated 10 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure under the industrial standard gives SCCR headroom for a panel fed from a transformer with moderate fault current. The C-curve trips between 5× and 10× In, so it won't nuisance-trip on capacitor or motor-start inrush but clears a hard short fast. Temperature derating is documented: 50 A at 35 °C, 48 A at 40 °C, 45.95 A at 50 °C, 43.8 A at 60 °C. If the panel ambient runs hot, the effective ampacity drops; a site electrical engineer should check the thermal curve before loading to 50 A in a sealed enclosure.

Frequently asked questions

Where can I buy 5SY4350-7KK11?

Sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of 5SY4350-7KK11?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher figure under the industrial standard governs SCCR coordination.

What compliance documentation is available for 5SY4350-7KK11?

The part carries IEC 60898 and IEC 60947-2 ratings, is halogen-free and silicon-free, and is designed for railway applications — documentation typically includes CE, UKCA, and EAC declarations per the SENTRON series. RoHS and REACH compliance is standard for Siemens industrial MCBs.

Will 5SY4350-7KK11 drop into a panel specified with 5SY4304-7CV?

Same SENTRON 5SY series, same 3-pole C-curve footprint (3 MW, 54 mm wide). The 5SY4350-7KK11 is the 50 A variant; 5SY4304-7CV is a lower-current sibling. No rewiring needed if the panel bus and load side are rated for 50 A — just verify the cable and upstream protection are sized accordingly.

MPN
5SY4350-7KK11