Skip to main content
Siemens 5SY4402-5 — 4-Pole MCB (DIN Rail)

Siemens 5SY4402-5 SENTRON MCB, 4P, 2A, Char. A

MPN5SY4402-5
Active

Siemens SENTRON 5SY4402-5 4-pole miniature circuit breaker, 2 A, 400 V AC, characteristic A, 10 kA / 35 kA breaking capacity.

$341.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4402-5 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4402-5 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY4402-5 — Protection
ParameterValue
Tripping characteristic (trip curve)A
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-235 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4402-5 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4402-5 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4402-5 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

If your BOM called for a 4P breaker in this frame, the 2 A rating is the first check: verify your load draw stays well under 2 A continuous.

Lockout and isolation — show me the rating

The 5SY4402-5 is sealable — it accepts a padlock hasp for positive lockout/tagout. If it's not locked, it's not safe. Overvoltage category III confirms it can handle distribution-level transients on the line side.

Mounting and enclosure fit

Depth is 76 mm, width 72 mm, height 90 mm — 4 modular width units (4 M). Mounting position any, fastening is via the quick assembly system (standard DIN rail). Installation depth 70 mm; vibration resistance tested to ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz.

Breaking capacity — match your SCCR

Breaking capacities: 10 kA, 35 kA AC, 15 kA DC, 5 kA (UL/CSA). Verify system SCCR does not exceed the applicable rating. Supply frequency 50/60 Hz; rated voltage 400 V AC (440 V multi-phase).

MPN
5SY4402-5