Skip to main content
Siemens 5SY4410-5 — 4-Pole MCB (DIN Rail)

Siemens 5SY4410-5 4-Pole MCB, 10 A, Char A, 10 kA

MPN5SY4410-5
Active

Siemens SENTRON 5SY4 series, 4-pole miniature circuit breaker, 10 A rated current, tripping characteristic A, 10 kA breaking capacity per EN 60898, 72 mm wide (4 width units).

$328.60Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4410-5 — Identification
ParameterValue
Type / order code5SY4
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4410-5 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC10 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4410-5 — Protection
ParameterValue
Tripping characteristic (trip curve)A
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4410-5 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4410-5 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4410-5 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

What the 10 A rating and characteristic A mean for your panel

The 5SY4410-5: The tripping characteristic A means it trips instantaneously on short-circuit currents between 2 and 3 times the rated current — this is the most sensitive characteristic available, designed to protect semiconductor circuits, measurement transformers, and other loads that cannot tolerate even brief overcurrents. For a 10 A breaker, that means the magnetic trip fires between 20 A and 30 A.

Physical fit and wiring constraints

Installation depth is 70 mm — the extra 6 mm accounts for the terminal screws protruding past the housing. Both top and bottom terminals are combined (phase and neutral can share the same clamp), and the terminals are sealable to prevent tamper after commissioning. Touch protection is built in per IP20 with connected conductors.

Frequently asked questions

Where can I buy the Siemens 5SY4410-5 and how do I get a price?

Submit your target quantity and delivery window for a current price quote — availability is confirmed at quote time, not from a live stock count.

Can the 5SY4410-5 replace a failed 4-pole MCB in an existing panel?

The characteristic A trip curve is more sensitive than standard B or C curves — verify the downstream loads are compatible with instantaneous trip between 20 A and 30 A.

MPN
5SY4410-5