Skip to main content
Siemens 5SY4413-6KK11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4413-6KK11 SENTRON MCB, 4P B-13A, 10kA

MPN5SY4413-6KK11

Siemens SENTRON 5SY4413-6KK11, 4-pole miniature circuit breaker, B-curve, 13 A rated current, 10 kA (EN 60898) / 20 kA (IEC 60947-2) breaking capacity, 400 V AC, 72 V DC max, IP20, quick-mount system.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4413-6KK11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4413-6KK11 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC13 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4413-6KK11 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4413-6KK11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4413-6KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4413-6KK11 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Three breaking-capacity ratings let you apply this MCB across different fault-level environments without oversizing. At 10 kA per EN 60898 it covers standard residential and commercial distribution boards. At 20 kA per IEC 60947-2 it meets industrial panel requirements where fault currents are higher — think motor control centers or sub-distribution near large transformers. The DC rating of 15 kA (IEC 60947-2) matters for railway DC auxiliary buses or battery-backed control circuits. The energy limiting class is 3, meaning it restricts let-through energy enough to protect downstream components in a selective coordination scheme.

Physical integration and environment

Ambient temperature range is -40 to +70 °C, storage down to -75 °C, with humidity limits up to 95% at 55 °C — no derating headache for outdoor cabinets or unheated enclosures.

Frequently asked questions

Where can I buy 5SY4413-6KK11 and get a price?

This part is sourced to order through independent distribution channels. Submit an RFQ to confirm current availability and pricing at quote time.

What are the key ratings of 5SY4413-6KK11?

4-pole B-curve MCB rated 13 A at 400 V AC, with breaking capacities of 10 kA (EN 60898), 20 kA (IEC 60947-2 AC), and 15 kA (IEC 60947-2 DC). Accepts 0.75–35 mm² conductors, IP20, DIN-rail mount.

Will 5SY4413-6KK11 drop into a panel specified around 5SY3132-6?

Both are SENTRON 4-pole MCBs on a 72 mm DIN-rail footprint, so the mechanical fit is the same. The 5SY4413-6KK11 carries a 13 A B-curve rating; verify that the 5SY3132-6's rating and curve match your branch circuit requirements before substituting.

MPN
5SY4413-6KK11