Siemens 5SY4413-7KK11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4413-7KK11 SENTRON MCB, 4P C-13A 10kA

MPN5SY4413-7KK11

Siemens SENTRON 5SY4413-7KK11 miniature circuit breaker, 4-pole, C tripping characteristic, 13 A rated current, 10 kA breaking capacity (EN 60898), 20 kA (IEC 60947-2).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4413-7KK11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4413-7KK11 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC13 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4413-7KK11 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4413-7KK11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4413-7KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4413-7KK11 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY4413-7KK11 is a SENTRON miniature circuit breaker (MCB) with four poles, a C tripping characteristic, and a 13 A rated current at 400 V AC. It breaks fault currents up to 10 kA per EN 60898 and 20 kA per IEC 60947-2, which covers most industrial panel branch circuits and motor feeder applications where the upstream transformer or supply impedance keeps prospective fault current under those thresholds.

Breaking capacity and trip curve

The 10 kA rating under EN 60898 is the standard for household and similar installations; the 20 kA rating under IEC 60947-2 is what matters for industrial control panels where higher fault currents are expected. Energy limiting class 3 means this MCB limits let-through energy enough that downstream components with lower short-circuit ratings can be coordinated, provided the prospective fault current stays within the 10 kA or 20 kA envelope.

The terminal accepts solid or stranded conductors from 0.75 mm² up to 35 mm² — that covers control wiring up through main feeder tails for a sub-distribution board. Combined terminals top and bottom, sealable, with touch protection per the product feature.

Rated for ambient temperatures from -40 °C to +70 °C, storage from -40 °C to +75 °C. Halogen-free and silicon-free construction, which matters for installations in rail, marine, or clean-room environments where outgassing or corrosion sensitivity is a concern. The design is explicitly for railway applications per the product design field.

Rated frequency 50/60 Hz. Maximum DC voltage rating is 72 V — usable on DC control circuits only up to that voltage, with a 15 kA breaking capacity per IEC 60947-2 on the DC side.

Frequently asked questions

What is the breaking capacity of 5SY4413-7KK11?

10 kA per EN 60898 and 20 kA per IEC 60947-2 at 400 V AC. For DC circuits up to 72 V, the breaking capacity is 15 kA per IEC 60947-2.

What wire sizes does 5SY4413-7KK11 accept?

Both solid and stranded conductors from 0.75 mm² up to 35 mm².

Where can I buy 5SY4413-7KK11?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for quotation to proceed.

What is the difference between 5SY4413-7KK11 and 5SY3132-6?

The 5SY3132-6 is a 2-pole C-curve MCB with a lower current rating and different pole count. The 5SY4413-7KK11 is a 4-pole unit at 13 A. They share the same SENTRON platform and DIN-rail footprint, but the pole count and rating differ — they are not drop-in replacements without rewiring.