Siemens 5SY4414-7KK11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4414-7KK11 SENTRON MCB, 4P C 0.3 A, 10/35 kA

MPN5SY4414-7KK11

Siemens SENTRON 5SY4414-7KK11, 4-pole miniature circuit breaker, C characteristic, 0.3 A rated current, 10 kA (EN 60898) / 35 kA (IEC 60947-2), IP20, -40 to 75 °C, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4414-7KK11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4414-7KK11 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC0.3 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY4414-7KK11 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-235 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4414-7KK11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4414-7KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

It's built for railway applications and general mechanical engineering and industry use.

The 0.3 A rating is low; this breaker protects a control transformer secondary or a small signal supply, not a main power feed. The 35 kA figure under 60947-2 gives you headroom on high-fault industrial panels where the prospective short-circuit current exceeds 10 kA. Temperature derating is published for the full range: 0.3 A at 35 °C, 0.29 A at 40 °C, 0.28 A at 45 °C, 0.27 A at 50 °C, 0.26 A at 55 °C, and 0.25 A at 60 °C. If your panel ambient runs 50 °C, size for 0.27 A continuous. Mounts in any position via the quick assembly system.

Snap-on DIN rail mounting with combined terminals top and bottom — wire incoming and outgoing on the same side if needed. Sealable for tamper-proof installations. Halogen-free and silicon-free construction reduces outgassing in sensitive environments like medical or clean-room panels.

Frequently asked questions

What is the breaking capacity of 5SY4414-7KK11?

It's rated 10 kA per EN 60898 and 35 kA per IEC 60947-2. Use the 35 kA figure for industrial panels where fault current exceeds 10 kA.

Where can I buy 5SY4414-7KK11?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SY4414-7KK11 drop into a panel specified around 5SY4304-7CV without rewiring?

Both are 4-pole SENTRON MCBs with the same form factor (4 MW), so mechanical fit on the DIN rail is identical. However, 5SY4414-7KK11 is a 0.3 A C-curve, while 5SY4304-7CV is a different rating — verify the trip characteristic and ampacity match your circuit before swapping.

MPN
5SY4414-7KK11