Skip to main content
Siemens 5SY4425-7CC11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4425-7CC11 SENTRON MCB, C-Curve 4P 10kA

MPN5SY4425-7CC11

Siemens SENTRON 5SY4425-7CC11, 4-pole miniature circuit breaker, C-curve, 10 kA breaking capacity per EN 60898, 400 V AC, 72 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4425-7CC11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4425-7CC11 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY4425-7CC11 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4425-7CC11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4425-7CC11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4425-7CC11 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.2 W

Product details

What this MCB is and where it fits

The Siemens 5SY4425-7CC11 is a 4-pole miniature circuit breaker from the SENTRON series, designed with a C-curve tripping characteristic and rated for 10 kA breaking capacity per EN 60898 at 400 V AC. It occupies 4 modular width units on a DIN rail and accepts supply from any direction, which simplifies panel layout when busbar routing is tight. The C-curve means it trips between 5 and 10 times rated current — the standard choice for general-purpose distribution circuits feeding motor starters, contactor coils, or lighting groups where moderate inrush is expected. The 10 kA short-circuit capacity at 400 V AC is the figure that governs selectivity coordination downstream; it matches the typical fault level at a sub-distribution board in an industrial or infrastructure installation.

Lifecycle and sourcing posture

This order code carries a current lifecycle stage. It is sourced to order against an RFQ through independent distribution channels — no minimum commitment, confirmed availability and pricing at quote time. For a BOM freeze or a spares replenishment, the 4-pole C-curve footprint and the 10 kA rating are the parameters to match; the railway-grade vibration spec and the halogen-free / silicon-free construction may also be requirements in the original specification.

Physical fit and panel integration

Width is 72 mm (4 modular units), depth 76 mm, height 90 mm, with an installation depth of 70 mm. The quick-assembly fastening method and combined top/bottom terminals mean the breaker clips onto the DIN rail and accepts busbar or wire entry from either end without reorienting the housing. Neutral conductor switching is not provided — this is a 4-pole protection device, not a switched-neutral MCB.

Frequently asked questions

Where can I buy 5SY4425-7CC11 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SY4425-7CC11 drop into a panel specified around 5SY5416-7 without rewiring?

Both are 4-pole C-curve MCBs in the SENTRON series with the same 4 MW width (72 mm), so the mechanical footprint is identical. The key difference is the breaking capacity rating — confirm that the 10 kA per EN 60898 of the 5SY4425-7CC11 meets the fault level at the point of installation; if the original spec required a higher SCCR, the 5SY5416-7 may have been selected for that reason.

What compliance documentation does this brand provide for 5SY4425-7CC11?

As a Siemens SENTRON product designed for railway applications and mechanical engineering, the MCB carries the applicable IEC and EN certifications (EN 60898 for breaking capacity, IEC 60068-2-6 for vibration). The halogen-free and silicon-free construction supports compliance with material restrictions common in rail and industrial specs. Specific RoHS/REACH declarations and the CE/UKCA mark are part of the standard documentation package available with the order.

MPN
5SY4425-7CC11