Skip to main content
Siemens 5SY4432-6CC11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4432-6CC11 SENTRON MCB, 4P, B-Curve, 10 kA

MPN5SY4432-6CC11

Siemens SENTRON 5SY4432-6CC11 miniature circuit breaker, 4-pole, B tripping characteristic, 10 kA breaking capacity per EN 60898, AC 50/60 Hz, 400/440 V, designed for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4432-6CC11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4432-6CC11 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY4432-6CC11 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4432-6CC11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4432-6CC11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4432-6CC11 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)3.2 W

Product details

The 4-pole design occupies 4 modular width units — 72 mm wide, 90 mm tall, 76 mm deep with a 70 mm installation depth. Combined terminals top and bottom simplify daisy-chaining busbars. Sealable for lockout/tagout compliance. Halogen-free and silicon-free — relevant if the panel sits in a clean room or oxygen-rich environment where silicone outgassing can foul contacts.

Electrical ratings and derating

Rated for AC operation at 50/60 Hz. The DC rating tops out at 72 V — useful for control circuits but not for high-voltage DC bus work. Power loss is 3.2 W per pole at rated current in hot operating state, so a 4-pole unit dissipates about 12.8 W total; factor that into enclosure thermal calculations if the panel is densely packed. Ambient temperature range is -40 to 75 °C, with humidity derating: max 95% RH up to 55 °C, 55% RH up to 70 °C, 35% RH up to 75 °C.

Frequently asked questions

Where can I buy 5SY4432-6CC11?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What is the breaking capacity of 5SY4432-6CC11?

The breaking capacity is 10 kA according to EN 60898, which is the standard for residential and light commercial MCBs. For higher fault currents, check the 5SY4 series with a 15 kA or 25 kA rating.

What compliance documentation does Siemens provide for 5SY4432-6CC11?

The part is designed for railway applications and carries vibration resistance tested to IEC 60068-2-6. It is halogen-free and silicon-free. For specific RoHS, REACH, or UL documentation, the manufacturer's standard declarations apply — request them with your RFQ.

MPN
5SY4432-6CC11