Skip to main content
Siemens 5SY4432-8CC11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4432-8CC11 SENTRON MCB, 4P D 32 A 10 kA

MPN5SY4432-8CC11

Siemens SENTRON 5SY4432-8CC11, 4-pole miniature circuit breaker, D tripping characteristic, rated 32 A / 400 V AC, 10 kA breaking capacity per EN 60898, IP20, 76 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4432-8CC11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4432-8CC11 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC32 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4432-8CC11 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4432-8CC11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4432-8CC11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4432-8CC11 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY4432-8CC11 is a SENTRON 4-pole miniature circuit breaker with a D tripping characteristic, rated 32 A at 400 V AC. The D-curve means it tolerates higher inrush currents — typical for motor, transformer, or welding loads where the start-up spike could nuisance-trip a B or C curve. Breaking capacity is 10 kA per EN 60898, which covers most distribution board fault levels in commercial and light industrial panels. The 4-pole design (4P) switches all three phases plus neutral, with no neutral conductor switching function — the neutral pole is switched but not protected.

Frequently asked questions

What is the breaking capacity of 5SY4432-8CC11?

Rated breaking capacity is 10 kA per EN 60898 at 400 V AC. For multi-phase operation the rated voltage is 440 V AC.

What conductor sizes does the 5SY4432-8CC11 accept?

Solid conductors from 0.75 to 35 mm² and stranded conductors from 0.75 to 35 mm². The screw terminals require a tightening torque of 2.5 to 3.5 N·m.

Where can I buy 5SY4432-8CC11 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

MPN
5SY4432-8CC11