Siemens 5SY4450-7 — Miniature Circuit Breakers (MCB)

Siemens 5SY4450-7 SENTRON MCB, 50 A, 4P, C-Curve, 10/15 kA

MPN5SY4450-7
Active

Siemens SENTRON 5SY4450-7, 4-pole miniature circuit breaker, 50 A rated, C tripping characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 4 MW wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4450-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SY4450-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

It switches and protects final circuits in commercial and industrial panels — motor starters, lighting distribution, control transformers — where the inrush from inductive or capacitive loads would nuisance-trip a B-curve device.

Breaking capacity and dual-standard rating

This breaker carries two interrupting ratings: 10 kA per EN 60898-1 and 15 kA per IEC 60947-2 / UL1077. The higher 15 kA figure applies when the part is specified as a circuit breaker for industrial control panels (IEC 60947-2); the 10 kA rating covers the same part used as a domestic-style MCB (EN 60898). For a 50 A 4-pole breaker on a 400 V supply with a transformer impedance of 4–5%, the prospective fault current at the panelboard typically lands between 6 and 12 kA — the 15 kA IEC rating gives headroom without stepping up to a larger frame.

Panel fit and environmental tolerance

Mounts in any position. Sealed with a lockable cover (sealable: yes). Rated IP20 with conductors connected — fine inside a locked panel, not for washdown zones. Ambient range -40 °C to 75 °C, with a derating curve starting at 35 °C: 50 A at 35 °C, 48 A at 40 °C, 45.95 A at 50 °C, 43.8 A at 60 °C. Halogen-free and silicon-free construction.

Frequently asked questions

What is the breaking capacity of 5SY4450-7?

10 kA per EN 60898-1 and 15 kA per IEC 60947-2 / UL1077 — the higher figure applies when the breaker is used in industrial control-panel applications.

Will 5SY4450-7 drop into a panel specified around 5SY4140-7?

Yes — both are 4-module-width (72 mm) SENTRON breakers with the same DIN-rail footprint, depth, and terminal layout. The 5SY4450-7 is the 50 A C-curve variant; the 5SY4140-7 is a 40 A C-curve. No rewiring or panel rework needed if the busbar and conductor sizing already support 50 A.

Where can I buy 5SY4450-7 and how is it quoted?

Sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not listed here.

What compliance documentation does Siemens provide for 5SY4450-7?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL1077. It is halogen-free and silicon-free. Full RoHS, REACH, and UL documentation is available from Siemens on request.