Siemens 5SY4502-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY4502-7 SENTRON MCB, C-Curve 2-Pole 10kA, 36mm Wid

MPN5SY4502-7
Active

Siemens SENTRON miniature circuit breaker, type 5SY4502-7, C-curve, 2-pole (1P+N), 10 kA per EN 60898-1 / 35 kA per IEC 60947-2, 36 mm wide, rated 230 V AC.

$13.97Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4502-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY4502-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY4502-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4502-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Rated at 230 V AC for single-phase operation (250 V max), it handles the usual 50/60 Hz supply found on the floor.

Breaking capacity — the number that matters for fault duty

This breaker carries two breaking-capacity ratings because it's certified to both the residential/light-commercial standard (EN 60898-1) and the industrial standard (IEC 60947-2). Under EN 60898-1 it's rated 10 kA at 230 V AC; under IEC 60947-2 it jumps to 35 kA at 230 V AC. For DC circuits, it's rated 15 kA at 60 V (72 V max). It also carries a UL 1077 / CSA C22.2 No.235 listing at 5 kA, so it's accepted in North American panels that recognize supplementary protectors. If your BOM calls for a breaker that meets both IEC and UL, this one covers both without a second line item.

Mounting and environmental fit

Snaps onto any DIN rail (the 'quick assembly system' fastening), and the combined top and bottom terminals let you daisy-chain busbars or wire in and out without extra jumpers. The sealable option (padlockable toggle) is handy for lockout/tagout on a machine circuit. Rated IP20 with conductors connected — that's typical for inside a closed panel, not for washdown areas.

Frequently asked questions

Where can I buy 5SY4502-7 and get a price?

The 5SY4502-7 is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

Will 5SY4502-7 drop into a panel specified around 5SY4140-7 without rewiring?

Yes, the 5SY4502-7 shares the same 36 mm width (2 modular units) and DIN-rail mounting as the 5SY4140-7, so it fits the same panel footprint and busbar layout. The key difference is the breaking capacity: the 5SY4502-7 offers 35 kA per IEC 60947-2 versus the lower-rated sibling, so verify your fault-current requirements before swapping.

What is the depth of the 5SY4502-7?

The overall depth is 76 mm; the installation depth behind the panel face is 70 mm.

What compliance documentation does Siemens provide for 5SY4502-7?

The breaker is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077/CSA C22.2 No.235. It is halogen-free and silicon-free. Standard documentation includes the Declaration of Conformity and CE marking.