Skip to main content
Siemens 5SY4502-7CV — 1-Pole MCB (DIN Rail)

Siemens 5SY4502-7CV MCB, 2-Pole, C-Char, 2 A, 15 kA

MPN5SY4502-7CV

Siemens 5SY4502-7CV, 2-pole miniature circuit breaker, C characteristic, 2 A rated current, 15 kA breaking capacity per IEC 60947-2, 2 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4502-7CV — Identification
ParameterValue
Number of poles2
Application suitabilityMechanical engineering / industry
5SY4502-7CV — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY4502-7CV — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4502-7CV — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Integrator's spec recap

The Siemens 5SY4502-7CV is a 2-pole miniature circuit breaker with a C tripping characteristic, rated 2 A at 50/60 Hz AC. It carries a 15 kA breaking capacity per IEC 60947-2, which means it can safely interrupt a fault current up to that level at the rated voltage — enough for most industrial panel feeder and branch circuits where the prospective short-circuit current is known to be within that limit. The C-curve (5–10× In) suits it for moderate inrush loads like small motors, transformers, or lighting banks. Rated current derates with ambient temperature: 2 A at 35 °C, 1.85 A at 40 °C, 1.78 A at 45 °C, 1.7 A at 50 °C, and 1.61 A at 55 °C. If the panel ambient runs above 35 °C, size the breaker for the derated value — a common oversight in tightly packed enclosures.

Panel fit and mounting

Snaps onto a standard DIN rail via the quick-assembly system; mounting position is any, so vertical or horizontal rail orientation works. Occupies 2 modular width units (36 mm wide). Depth is 76 mm, installation depth 70 mm — verify clearance behind the rail, especially in shallow enclosures. The combined top and bottom terminals accept neutral conductor switching, and the sealable cover allows panel-lockout for tamper-proof isolation.

Environmental and compliance

Rated for a wide ambient range: -40 °C to 75 °C, with humidity limits per the surrounding temperature influence curve. IP20 protection (with connected conductors) — suitable for dry indoor panel environments, not for washdown or outdoor exposure. Halogen-free and silicon-free construction, degree of pollution 3, overvoltage category III. Suitability for operation includes mechanical engineering and industry. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

Frequently asked questions

What is the breaking capacity of 5SY4502-7CV?

15 kA per IEC 60947-2.

What is the difference between 5SY4502-7CV and 5SY4301-7CV?

The 5SY4301-7CV is a 1-pole version; the 5SY4502-7CV is 2-pole. Both share the same C-curve, 2 A rating, and 15 kA breaking capacity. The 2-pole unit occupies 2 modular widths instead of 1, and includes neutral conductor switching. Panel fit is otherwise identical — same depth and mounting system.

Where can I buy 5SY4502-7CV?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN