Siemens 5SY4502-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY4502-8 SENTRON MCB, D-curve 2 A 1P+N, 10 kA IEC

MPN5SY4502-8
Active

Siemens SENTRON 5SY4502-8 miniature circuit breaker, D-curve, 2 A rated, 1P+N, 10 kA (IEC 60898) / 35 kA (IEC 60947-2), 2 MW (36 mm) wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4502-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY4502-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4502-8 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4502-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY4502-8 is a D-curve miniature circuit breaker rated at 2 A AC, 1P+N (switched neutral), occupying 2 modular width units (36 mm) on a DIN rail. It carries a 10 kA breaking capacity per IEC 60898-1 and 35 kA per IEC 60947-2 / UL1077, making it suitable for high-fault-current industrial panels where the D-curve delays tripping on inrush — typical for motor-starting or transformer-fed loads.

D-curve and derating — what matters for panel fit

The D-curve characteristic (tripping between 10× and 20× In) is designed to ride through the high inrush of motor-starting or transformer primary energisation without nuisance trips. At 2 A rated, that means the magnetic trip holds up to roughly 20–40 A peak. The thermal derating is published: 2 A at 35 °C, 1.9 A at 40 °C, 1.85 A at 45 °C, 1.8 A at 50 °C, 1.75 A at 55 °C, and 1.7 A at 60 °C — so in a warm enclosure, size up accordingly if continuous load approaches the 2 A line.

Snap-on 36 mm width (2 MW) fits standard DIN-rail enclosures. IP20 with connected conductors.

Frequently asked questions

Where can I buy 5SY4502-8?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 5SY4502-8 drop into a panel specified around 5SY4115-7CV without rewiring?

Both are 2 MW (36 mm) wide SENTRON MCBs with the same DIN-rail footprint and terminal layout, so physical fit is identical — but verify the rating and curve: 5SY4115-7CV is a B-curve 15 A, while this is a D-curve 2 A. If the panel was wired for 15 A B-curve, the 2 A D-curve will not carry the same load and the curve difference changes coordination.

MPN
5SY4502-8