Siemens 5SY4503-8CC11 — 1-Pole MCB (DIN Rail)

Siemens 5SY4503-8CC11 SENTRON MCB, 2-pole 3A D-curve, 10kA

MPN5SY4503-8CC11

Siemens SENTRON 5SY4503-8CC11 miniature circuit breaker, 2-pole (1P+N), 3 A rated current, D tripping characteristic, 10 kA breaking capacity at 230 V AC, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4503-8CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityMechanical engineering / industry
5SY4503-8CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Overvoltage categoryIII
5SY4503-8CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SY4503-8CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

It breaks 10 kA at 230 V AC per EN 60898, which means it handles high inrush loads like motor starters or transformer primaries without nuisance tripping — the D curve allows 10–20× rated current for short spikes. Designed for railway applications, it carries an overvoltage category III rating and operates from -40 to +70 °C ambient.

Terminals accept 0.75 to 35 mm² solid or stranded copper, torqued to 2.5–3.5 N·m. Both top and bottom have combined terminals (neutral and phase), and the neutral pole is switched. Sealable and touch-protected per IP20 with connected conductors.

Halogen-free and silicon-free construction. Storage range -40 to +75 °C; ambient operating range -40 to +70 °C. Humidity tolerance: max 95% at 55 °C, derating to 55% at 70 °C and 35% at 75 °C. Mounting position any; power supply cord position any. Designed per DIN EN 61346-2 and DIN EN 81346-2 (function code F).

Frequently asked questions

What is the breaking capacity of 5SY4503-8CC11?

10 kA at 230 V AC per EN 60898, with a maximum DC voltage of 72 V.

What wire sizes does the 5SY4503-8CC11 accept?

Solid or stranded copper from 0.75 mm² up to 35 mm², torqued to 2.5–3.5 N·m.

Where can I buy 5SY4503-8CC11 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Submit a request with target quantity for availability and current pricing.

Will 5SY4503-8CC11 drop into a panel specified around 5SY3132-6 without rewiring?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint, but the 5SY4503-8CC11 is a 1P+N design with a switched neutral, while the 5SY3132-6 is a 2-pole without neutral switching. Verify the panel's neutral bus wiring before substitution.